Vigitron MaxiiFiber Vi5004 Installation Manual Download Page 1

Vi5004 4-Port Media Converter Installation Manual

 

Application Drawing 

Important Safety Warning

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

Ethernet Switch/NVR-end Installation

- Connect an approved 12VDC power supply to the power connector of 

 Vi5004. A power adapter connector is provided to simplify connection.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

 Ethernet port of Vi5004 using a standard Cat5/6 cable of maximum 

 328 feet (100 m) in length.

- Insert a suitable 100MBps SFP into the SFP socket of the Vi5004.  The 

 SFP needs to match the specification of the fiber optics cable.

- Connect one end of the long fiber optic cable to a SFP module.

The Ethernet link, Fiber link, activity LEDs should be "ON"  and "Blink" to 

indicate the status of each port.

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should conform

  to all local codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.

- To reduce the risk of fire or electrical shock, do not expose these products to rain, 

  moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.

- DO NOT install the unit in a place where the operating ambient tempera ture

  exceeds 70° C.

- Make sure that the external power supply output voltage is in the recommended 

  range. 

- Do not install near any heat sources such as radiators, heat registers,  stoves or 

  other apparatus that produce heat.

- Protect the power cord from being walked on or pinched particularly at plugs,

  convenience receptacles, and the point where they exit from the apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long periods of 

  time.

- Refer all servicing to qualified service personnel. Servicing is required when the

  apparatus has been damaged in any way, such as a power supply cord or plug is

  damaged, liquid has been spilled, or objects have fallen into the apparatus, the

  apparatus has been exposed to rain or moisture, does not operate normally, or has

  been dropped.

- The powe plug is used as the disconnect device and shall remain readily operable.

Vi5004-UM

Vigitron’s Vi5004 is a 4-port fiber optic media convertor that enables Ethernet 

signals to be transmitted over fiber optic cables.  It enable UTP Ethernet to 

connect to fiber to meet long distance transmission requirement or where 

fiber is already installed. The use of fiber SFPs  enables compatibility with all 

major single and multimode fiber optics cables to achieve transmission 

distances depending on the cable and SFP type.  The Vi5004 can use 

virtually any MSA compliant SFPs. 
The Vi5004 is an ideal solution for converting existing analog fiber 

infrastructures to IP systems. It provides a unique, reliable, and cost effective 

solution to meet long distance transmission application requirements.  Up to 

four Vi5004 units can be instaled in a Vi5000R rackmount shelf to povide up 

to 16 ports of rack mountable fiber optics media converters.  

- Insert a suitable 100MBps SFP into the SFP socket of the Vi5001.  The 

 SFP needs to match the specification of the fiber optics cable.

- Connect the fiber connector of the optical wire to the SFP.

- If the IP Camera is non-PoE use an approved 12VDC or 48VDC power

 adapter to power the Vi5001.

- If the IP Camera is PoE enabled use the Vi0017 or another approved 

 48VDC power adapter to power the Vi5001.

- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port 

 of Vi5001 using a standard 

Cat5/6 cable of maximum 100m in length.

Cat 5/6

Fiber Optics

Network Switch

Adding fiber optic connection to Network switches

Data

Long Distance Fiber

PoE Camera

PoE Camera

Vi5001

Vi5004

Power

Supply

Data

Long Distance Fiber

Vi5001

Power

Supply

Data

Long Distance Fiber

PoE Camera

Vi5001

Power

Supply

Data

Long Distance Fiber

PoE Camera

Vi5001

Power

Supply

Data +

 PoE

328 ft. (100m)

Data +

 PoE

328 ft. (100m)

Data +

 PoE

328 ft. (100m)

Data +

 PoE

328 ft. (100m)

Power

Supply

The Vi5004 along with Vi5001 enables addging 100Base-T fiber connection to any network 

switch. Each port of Vi5004 can be individually powered by PoE or local power supply SFPs 

need to be added to Vi5004 and Vi5001 to match the fiber optic cables.   

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

Max

ii

 

Fiber

TM

Rack mount four 4-port Vigitron transmission devices

The Vi5000R provies an easy way to rack mount up to four Vi5004s to make a 16 port media 

converter. The Vi5000B can be used to cover empty spaces of Vi5000R.

Vi5004

Vi5004

4 x Vi5000R

Vi5000R

Vi5004

Vi5004

Reviews: