background image

Vi5001 Fiber Media convertor with 30W PoE Installation 

 

Application Drawing 

Important Safety Warning

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

Ethernet Switch/NVR-end Installation

- Connect an approved 12VDC power supply to the power connector of

 Vi5001. A power adapter connector is provided to simplify connection.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

 Ethernet port of Vi5001 using a standard Cat5/6 cable of maximum 

 328 feet (100 m) in length.

- Connect one end of the long fiber optic cable to a SFP module, then 

 connect the SFP module to the SFP socket of Vi5001.

The Ethernet link, Fiber link, activity LEDs should be "ON"  and "Blink" to 

indicate the status of each port.

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should 

  conform to all local codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage

  wiring.

- To reduce the risk of fire or electrical shock, do not expose these products 

  to rain, moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron

  equipment.

- DO NOT install the unit in a place where the operating ambient tempera

  ture exceeds 70° C.

- Make sure that the external power supply output voltage is in the recom

  mended range. 

- Do not install near any heat sources such as radiators, heat registers, 

  stoves or other apparatus (including DVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at 

  plugs, convenience receptacles, and the point where they exit from the 

  apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long 

  periods of time.

- Refer all servicing to qualified service personnel. Servicing is required

  when the apparatus has been damaged in any way, such as a power 

  supply cord or plug is damaged, liquid has been spilled, or objects have

  fallen into the apparatus, the apparatus has been exposed to rain or 

  moisture, does not operate normally, or has been dropped.

- The powe plug is used as the disconnect device and shall remain readily

  operable.

Vi5001_UM

Vigitron’s Vi5001 is a media converter that enables Ethernet signals to be 

transmitted over fiber optic cables to meet long distance transmission  

applications or reusing existing analog fiber connections for IP applica-

tions. The use of SFP fiber modules resulting in compatibility with all 

major single-mode and multi-mode fiber optics cables to achieve 

transmission distances depending on the cable and SFP. The Vi5001 also 

provides IEEE 802.3af/at PoE up to 30W to the connected IP device such 

as IP camera swhen used with appropriate power supplies. 
The Vi5001 is an ideal solution for converting existing analog fiber 

infrastructures to IP systems. It provides a unique, reliable, and cost 

effective solution to combine a variety of transmission methods to meet 

any application requirement.

- Insert a suitable 100MBps SFP into the SFP socket of the Vi5001.  The 

 SFP needs to match the specification of the fiber optics cable.

- Connect the fiber connector of the optical wire to the SFP.

- If the IP Camera is non-PoE use an approved 12VDC or 48VDC power

 adapter to power the Vi5001.

- If the IP Camera is a PoE enabled use the Vi0017 or another approved 

 48VDC power adapter to power the Vi5001.

- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port 

 of Vi5001 using a standard Cat5/6 cable of maximum 100m in length.

Max

ii

 

Fiber

TM

Connecting and powering IP Cameras over Fiber cables

Data

up to 80Km

Cat 5/6

Fiber Optics

+

SFP

+

SFP

Data + 

PoE

328 ft. (100m)

Data + 

PoE

328 ft. (100m)

Connecting and powering IP Cameras over Fiber cables

Fiber Switch

Data

up to 80Km

Vi5000

+

SFP

+

SFP

Data + 

PoE

328 ft. (100m)

Power

Supply

PoE Camera

PoE Camera

Vi5001

Vi5001

Vi0012

Power

Supply

Vi0017

56VDC

12VDC

Power

Supply

The Vi5001s are used for long distance high bandwidth transmission applications. The 

Vi5001 provides up to 30W PoE power to meet the high power requirements. of PoE 

PoE Switch

By using the SFPs, the Vi5001 will be compatible with most installed fiber types and can be 

directly connected to SFP modules installed in network switches.