Vigitron MaxiiCopper Mini Model Vi2400WP Installation Manual Download Page 1

 

 

Application Drawing 

Vi2400A Ethernet Extender over Coax Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

The MaxiiCopper Mini Model Vi2400A is a very compact data transmission 

device that extends full-duplex High-Speed Ethernet over existing coax 

infrastructures. It extends 10BaseT signals up to 5,000 ft (1,524m) and 

100BaseT up to 1,800 ft (548m). It can fit in most camera housings and 

junction boxes. With Pass Through PoE (PTP™), it can handle up to 30W 

PoE power. It employs 

MaxiiCopper

 innovative and unique Ethernet 

extension technology that is designed to take full advantage of high-band-

width networking cables and maintain a full-duplex 10 or 100Mb/s Ethernet 

connection up to the maximum range with minimum transmission error and 

latency. Vi2400A can connect multiple remote network devices such as 

Mega-pixel IP cameras or VoIP to a central LAN switching fabric with ease.  

Its automatic dual-rate capability feature balances the best possible network 

throughput and long-reach distance.
The Vi2400A is a transmitter device and needs to be deployed on the 

camera end.  The data rate between the remote and central locations is 

automatically set based on the distance. It is equipped with LEDs to provide 

link status and configured data rate.  No IP setting or configurations are 

required and it is completely transparent to the corporate IP network and 

higher layer protocols. The Coax cable needs to be point to point without 

any branches and multiple segments can be joined together using barrel 

connectors. 

Important Safety Warning

- Ground the unit through the earth ground screw.

- Connect the IP camera RJ45 connector to the 10/100BaseT Ethernet port 

  of Vi2400A using a standard Cat5/6 cable of maximum 100 m in length.

- Connect one end of the long coax cable to the BNC connector of 

  Vi2400A.
The link LED on the 10/100 connector should be “ON” to indicate proper 

connection between the camera and Vi2400A. 

Ethernet Switch/NVR-end Installation

- Use a Vi2401A/Vi2404A/Vi2408A or Vi2416A on the receiving side.

- If using a Vi2401A set the Master/Slave dip switch to “Slave” mode and

  Set the Remote/Local switch to Local.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

  Ethernet port of Vi2401A using a standard Cat5/6 cable of maximum 

  100 m in length.

- Connect one end of the long coax cable to the BNC connector of Vi24xxA.
The link LED on the 10/100 Ethernet connector should be “ON” to indicate 

proper connection between the switch and Vi24xxA. Also the Traffic LED 

on the Coax side should be on and flashing to indicate proper connection.  

While the Link LED, Orange for 100BaseT and Green for 10BaseT, in a 

steady state will indicate confirmed connection between extenders. 

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should 

  conform to all local codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage

  wiring.

- To reduce the risk of fire or electrical shock, do not expose these products 

  to rain, moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron

  equipment.

- DO NOT install the unit in a place where the operating ambient tempera

  ture exceeds 75°C.

- Make sure that the external power supply output voltage is in the recom

  mended range. 

- Do not install near any heat sources such as radiators, heat registers, 

  stoves or other apparatus (including DVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at 

  plugs, convenience receptacles, and the point where they exit from the 

  apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long 

  periods of time.

- Refer all servicing to qualified service personnel. Servicing is required

  when the apparatus has been damaged in any way, such as a power 

  supply cord or plug is damaged, liquid has been spilled, or objects have

  fallen into the apparatus, the apparatus has been exposed to rain or 

  moisture, does not operate normally, or has been dropped.

- The mains plug is used as the disconnect device and shall remain readily

  operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

Network Switch

Vi2404A

Data + 

PoE

328 ft. (100m)

Data + 

PoE

328 ft. (100m)

PoE Cameras

Data + 

PoE

328 ft. (100m)

Data + 

PoE

Extended Coax

Data + 

PoE

Extended Coax

Data + 

PoE

Extended Coax

Vi2400A

Data + 

PoE

328 ft. (100m)

Vi2400A

Vi2400A

Vi2401A

Vi2400WP

Max

ii

 

Copper

TM

Reviews: