Technical Specifications 

 

Power Supply 

 Input- 4.5 v  (3-Cell,each 1.5v) 

Input  

Test Key       

Indication  

LED indication for following Status. 

 

Green

 LED: Power ON Condition 

 

Red

 LED: Alarm Condition 

Output 

Buzzer Output : 

> 85 decibels (dB) at 3m 

Size 

( 111x89x38)mm  (  L x H x W ) 

Operating Temperature 

-20C° to 55C°  

Humidity 

0 to 95 % Rh.  

  

 
 

 

 

 

Summary of Contents for TrueSense CO-DETECTOR

Page 1: ...rta in Website http www vighnaharta in Doc No TSCO_UM_1_1 Rev No 1_1 Eff Date 04 11 2015 Prepared By Ganesh Approved By CO DETECTOR USER MANUAL Mfg By Vighnaharta Technologies Pvt Ltd 2nd Floor Karanjkar Estate S N 11 11 Nanded Gaon Pune 411041 Contact no 919011033259 Landline Sales 919011033260 Email sales vighnaharta in Website http www vighnaharta in ...

Page 2: ...TrueSafe CO User Manual Vighnaharta Technologies Pvt Ltd Page 2 of 8 Table Of Contents Overview III Technical Specifications IV Installation Procedure V Getting Started VI How does Co Detector work VII ...

Page 3: ...remises System can sense dangerous levels of Carbon Monoxide gas through sensor It provides visual and audible indications to user It shows RED signal and sounds buzzer when dangerous level of Carbon Monoxide occurs It is battery operated device and features like power on indication and low battery indications have been provided with this CO Detector Highlighted Features Detect dangerous level of ...

Page 4: ...cations Power Supply Input 4 5 v 3 Cell each 1 5v Input Test Key Indication LED indication for following Status Green LED Power ON Condition Red LED Alarm Condition Output Buzzer Output 85 decibels dB at 3m Size 111x89x38 mm L x H x W Operating Temperature 20C to 55C Humidity 0 to 95 Rh ...

Page 5: ...ion Procedure To install the unit at the user premises 1 Level the cabinet on sturdy wall and mark the mounting holes with a pencil Note The height of the unit from the flooring must be high 2 Insert the screws into the mounting hole partially and hang the cabinet on middle hole ...

Page 6: ... minute shows that the system is ON 3 Test Key Can be Use to Test Co Detector 4 ON OFF Switch To Power ON and OFF the CO Detector 5 End battery life Buzzer will be beep once per minute Power ON the Co Detector To power the system Use ON OFF switch Separate switch has been provided to power ON and OFF the Co Detector When user power ON the Co Detector then System will check itself and it will show ...

Page 7: ...e are following indications to user 1 Idle Condition 2 Alarm Condition 3 Self Test 4 End of Battery Life Ideal Condition Ideal condition is nothing but enabling the system for alerting the user against emergencies In this condition the Co Detector scan the surrounding environment through Co Sensor The GREEN LED blink every minute to show that system is power ON Alarm Condition Alarm condition is n...

Page 8: ...OFF One Beep every Minute Return to Normal Operation When the Carbon Monoxide gas disperses the alarm signal will stop The green power lamp will continue to flash approximately once every minute The above chart shows different operational modes of CO detector with their working function The Co Detector designed according to UL3024 standard and alarm conditions provided according to COHB in human b...

Reviews: