ViewSonic Corporation
Confidential - Do Not Copy
N2201w-1M
21
1.5. TV receiving test:
1.5.1 TV SIGNAL TEST ITEM
CENTRALISM TRANSMITTING SIGNAL CHECK CONTENT
SET CONTENT
CHANNEL
ORDER
FREQUENCY
(MHz)
PATTERN
SOUND
P/S(dB)
CHECK
CONTENT
CHANNEL 2
55.25 MONO SCOPE SWEEP TONE -10 ELECTRIC
ABNORMITY SOUND
CHANNEL 6
83.25 COLOR BAR 400Hz -10 SOUND ,PICTURE
CHANNEL 7
175.25 Full White (100
IRE)
STEREO -10 STERO FUNCTION
CHANNEL 13
211.25 STAIR DUAL -10 SUB FUNCTION
CHANNEL 14
471.25 MULTIBURST MONO -16 IMAGE AND SOUND
DISTURB
CHANNEL 36
603.25 MULTIBURST MONO -10 TEST Close-caption T1
FUNCTION
CHANNEL 69
801.25 MONO SCOPE MONO(1KHz) -10 NOISE LIMMITTED
SENSITIVITY
TV TEST METHOD
A.CHANNEL2 Examines sound by ear, whether the sound does have mechanical resonation and the
electrical unusual sound, and image to sound disturbance.
B.CHANNEL6: Check sound and picture.
C.CHANNEL7: Examines whether the sound does receive the image disturbance, Judgment basis:
Whether there is unusual sound, input signal LEVEL<=36dBu,and STEREO SENSITIVITY is normal.
D.CHANNEL13: Under main/sub/main-sub mode, check sub function.
E.CHANNEL14: Examines whether the sound does receive the image disturbance, Judgment basis:
Whether there is unusual sound.
F. CHANNEL 36:Check T1 of close-caption. Input signal level<=45dBu.
G.CHANNEL 69: Adjustment attenuator, If the critical point of the change of the image signal to noise
ratio is under LEVEL<=60dBu, regards as normally.
PRODUCTS OUTPUT CHECK ITEM.
A. The same as " CENTRALISM TRANSMITTING SIGNAL CHECK CONTENT"
B. saturation TEST, inputs the TV signal, the input signal LEVEL establishment most greatly is
90dBu,check whether CONTRAST of the image is normal; Whether appears the disturbance
phenomenon.
C.AFT CHECK,
(1) The frequency of the input TV signal is 211.25MHz (CH13), after confirmed the TV set receives
this signal, closure radio station; Then set frequency of the TV signal generator to be 212.25MHz,
turn on the TV set and check whether the TV set receives the signal of CH13.
(2). The frequency of the input TV signal is 211.25MHz (CH13), after confirmed the TV set receives
this signal, closure radio station; Then set frequency of the TV signal generator to be 212.00MHz,
turn on the TV set and check whether the TV set receives the signal of CH13.
(3). After all of FUNCTION TEST completed, we must erase all saved changes again and restore the
factory defaults.
TIMING TABLE (FACTORY PRESET MODE) (TABLE 2)
Mode Resolution
Horizontal
Frequency
Vertical
Frequency
Pixel
Frequency
)
z
H
M
(
)
z
H
(
)
z
H
k
(
640x480@60 Hz
31.469
59.940
25.175
640x480@72 Hz
37.861
72.809
31.500
VGA
640x480@75Hz 37.500
75.000
31.500
800x600@56Hz 35.156
56.250
36.000
800x600@60Hz 37.879
60.317
40.000
800x600@72Hz 48.077
72.188
50.000
SVGA
800x600@75Hz 46.875
75.000
49.500
1024x768@60Hz 48.363 60.004 65.000
1024x768@70Hz 56.467 70.069 75.000
XGA
1024x768@75Hz 60.023 75.029 78.750
1280x1024@60Hz 63.981 60.020 108.000
XGA
1280x1024@75Hz 79.974 75.024 135.000
WXGA 1440x900@60Hz
29.830
60.019
31.500
UXGA 1680x1050@60Hz
65.290
59.950
146.250