background image

7

3. 

Route the cable to terminals X11
and X13 on the PCB.

4. 

Plug connectors X11 and X13 into
the PCB. Insert the strain relief.

5. 

Connect the connector to the WiFi
module. Insert the WiFi module into
the control unit support from below.

6. 

Close the control unit enclosure
and the Vitodens in reverse order –
see pages 4 and 5.

7. 

Start up the WiFi module – see
page 11.

Installing the WiFi module in the Vitopend

Opening the control unit enclosure

!

Please note

Electronic assemblies can be
damaged by electrostatic dis-
charge.

Prior to commencing any work,
touch earthed objects such as
heating or water pipes to dis-
charge static loads.

1.

1. 

Undo the screw and push the con-
trol unit downwards.

 

Installing the WiFi module in the Vitodens

 (cont.)

5838175

Summary of Contents for WiFi module

Page 1: ...Installation instructions for contractors VIESMANN WiFi module For installation in the Vitodens and Vitopend control unit support WiFi module 5838175 GB 1 2019 Please keep safe ...

Page 2: ...by a competent person heating engineer installation contrac tor Before working on the equipment heat ing system isolate the power supply e g by removing a separate mains fuse or by means of a mains isolator and safeguard against unauthorised reconnection When using gas as fuel also close the main gas shut off valve and safeguard against unauthorised reopening Repairing components which fulfil a sa...

Page 3: ...rol unit enclosure 7 Installing the WiFi module 9 Starting up the WiFi module Symbols on display in connection with WiFi module 11 Connecting the control unit to the WiFi 11 Activating the WiFi module via key combination 11 Activating the WiFi module via the menu 12 Connecting the heating system to WiFi and the Viessmann server 12 Symbols shown during operation 13 Troubleshooting 14 Software licen...

Page 4: ...4 Opening the Vitodens 2x 2 1 Installing the WiFi module in the Vitodens 5838175 ...

Page 5: ... 4x Please note Electronic assemblies can be damaged by electrostatic dis charge Prior to commencing any work touch earthed objects such as heating or water pipes to dis charge static loads Installing the WiFi module in the Vitodens cont 5838175 ...

Page 6: ... X13 X111 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 X13 X11 2 1 Pull the dummy adaptor out down wards 2 Remove the diaphragm grommet and reinsert it with the cable Installing the WiFi module in the Vitodens cont 5838175 ...

Page 7: ... and the Vitodens in reverse order see pages 4 and 5 7 Start up the WiFi module see page 11 Installing the WiFi module in the Vitopend Opening the control unit enclosure Please note Electronic assemblies can be damaged by electrostatic dis charge Prior to commencing any work touch earthed objects such as heating or water pipes to dis charge static loads 1 1 Undo the screw and push the con trol uni...

Page 8: ...8 2 2 Pivot the control unit forwards 3 2x 4 3 Release the locking tabs on the control unit enclosure 4 Remove the wiring chamber cover Installing the WiFi module in the Vitopend cont 5838175 ...

Page 9: ...9 Installing the WiFi module 4 X13 X11 1 X11 X10 X13 X111 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 T00 X13 X11 3 2 Installing the WiFi module in the Vitopend cont 5838175 ...

Page 10: ... relief 3 Plug connectors X11 and X13 into the PCB 4 Connect the connector to the WiFi module Insert the WiFi module into the control unit support from below 5 Close the control unit enclosure in reverse order see page 7 6 Start up the WiFi module see page 11 Installing the WiFi module in the Vitopend cont 5838175 ...

Page 11: ... Activating the WiFi module via key combination Press MODE and OK simultane ously and hold for at least 5 seconds until On or OFF appears on the display Release the buttons and the change will be accepted If the WiFi module has been switched on for the first time it is in access point mode so that it can be configured via the associated Viessmann app See chapter Connecting the heating sys tem to W...

Page 12: ...nn app See the following chapter Connecting the heating system to WiFi and the Viessmann server The heating system is registered on the Viessmann server via the relevant Viessmann app 1 Ask the system user to install the relevant Viessmann app on their smartphone or tablet 2 Launch the Viessmann app and fol low the instructions it gives Displayed on the boiler control unit The message COnn is disp...

Page 13: ...le is active and connected to the rout er Permanently on WiFi module active in access point mode Flashing alter nately Time synchronisation via NTP server running Flashing syn chronously Establishing a connection to the Viessmann server Permanently on Connection to Viessmann server active and time synchronised Connecting the control unit to the WiFi cont 5838175 ...

Page 14: ...could be establish ed after more than 5 minutes Possible reasons No authorisation for port 123 UDP on the WiFi router firewall of the system user Name resolution DNS does not work Check the settings on the WiFi router of the system user H03 Internal error Activating access point mode Press the following buttons 1 Press MODE and simultaneously and hold for at least 5 seconds until the following dis...

Page 15: ...formation see mes sages in the app Reinstating the delivered condition Resetting the WiFi module Note Only possible if the WiFi module is acti vated Press the following buttons 1 Press MODE and simultaneously and hold for at least 5 seconds until the following display appears 2 Press MODE within 5 seconds until the following display appears 3 until P06 is displayed 4 OK to confirm 5 until rES appe...

Page 16: ...tphone to the internal WiFi of the WiFi module For the WiFi SSID and the WPA2 password see the label on the WiFi module 2 Open the internet browser on the smartphone and enter the address http vitoconnect gateway 3 Follow the instructions on the web site Troubleshooting cont 5838175 ...

Page 17: ...duct includes soft ware developed by the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org This product includes cryptographic software written by Eric Young eay cryptsoft com and software written by Tim Hudson tjh cryptsoft com 3 Disclaimer The open source software contained in this package is distributed WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABIL ITY...

Page 18: ...5 Contact information Viessmann Werke GmbH Co KG 35107 Allendorf Germany Fax 49 64 52 70 27 80 Phone 49 64 52 70 0 open source software support viessmann com www viessmann de Software licences cont 5838175 ...

Page 19: ...19 5838175 ...

Page 20: ... Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5838175 Subject to technical modifications ...

Reviews: