If there is damage to the connecting
cables or lines of the appliance or exter-
nally installed accessories, these must
be replaced with special cables or lines.
Only use Viessmann cables / lines as
replacement. For this, notify your quali-
fied contractor.

Upkeep

Damaged cables / lines

5608 437 GB

Summary of Contents for VITOSOLIC 200

Page 1: ...Operating instructions for the system user VIESMANN Control unit for solar thermal systems VITOSOLIC 200 5608 437 GB 4 2014 Please keep safe ...

Page 2: ...e appliance Never permit children to play with the appliance Cleaning and maintenance must not be carried out by unsupervised children Appliance connection The appliance may only be connected and commissioned by authorised con tractors Observe the specified electrical con nection requirements Modifications to the existing installa tion may only be carried out by author ised contractors Danger Inco...

Page 3: ...s Please note Components that were not tested with the system may cause sys tem damage or may affect its functions Have all installation or replace ment work carried out by qualified contractors Safety instructions For your safety cont 5608 437 GB ...

Page 4: ...amount 9 What to do if The solar thermal system does not start 11 There is no DHW available 11 The display is dark 12 The display illumination flashes 12 Calling up faults 12 Upkeep Inspection and maintenance 13 DHW cylinder if installed 13 Safety valve DHW cylinder 13 Potable water filter if installed 13 Damaged cables lines 14 Menu overview 15 Index Index 5608 437 GB ...

Page 5: ...ing of the control unit to local conditions and to building characteristics plus the instruc tion of the user in operating the system must be carried out by your heating con tractor Introductory information Commissioning 5608 437 GB ...

Page 6: ... setting Takes you to the previous step in the menu or cancels a setting that has been started Cursor keys To scroll through the menu Cursor keys To adjust values To change between standard dis play and main menu The display only shows 4 lines of text The arrow on the left of the display high lights the available menu item Use to scroll through the menu Operation Operation 5608 437 GB ...

Page 7: ...d Additional function for DHW heating Time Date Relay Condition of relays Sensors Temperature at the respective sensor in C Note If the sensor inputs are not connected the breaking value in dicating a lead break is displayed Intens Radiation intensity in conjunction with a solar cell Note If the input is not connected the breaking value indicating a lead break is displayed A diagram in the standar...

Page 8: ...lt at the solar control unit Loading cyl only with several consum ers The display shows which consumer is being heated Pause cyl only with several consum ers Only if the Cyclical heating function has been ena bled by your heating contractor Pause in the heating of the displayed consumer Cyl set The consumer displayed has reached its set value Fault A fault has occurred at the solar control unit to...

Page 9: ...um cylinder temperature for additional consumers e g 2nd DHW cylinder in C Relay 1 to Relay 7 Hours run of the actuators connected at the relay e g solar circuit pump at R1 Days Days in operation solar control unit To reset the values except value for days in operation Whilst the value is displayed press the following keys 1 OK Delete Yes is displayed 2 OK to confirm Calling up the heat amount Pre...

Page 10: ...mount in MWh Note Add the heat values together The values are not calibrated If there is a power failure the displayed value showing the heat amount may be up to 6 hours old To reset the heat amount values Whilst the value is displayed press the following keys 1 OK Delete Yes is displayed 2 OK to confirm Scanning options Calling up the heat amount cont 5608 437 GB ...

Page 11: ...rm 6 Press the keys for Auto 7 Press OK to confirm 8 Press until Main menu is dis played There is no DHW available Cause Remedy The solar control unit is faulty Inform your local heating contractor Collector temperature is too high safety shutdown by the solar control unit Wait until the collector temperature has dropped The set cylinder temperature set DHW temperature has been set too low Inform ...

Page 12: ...Calling up faults If any faults have occurred in your solar thermal system the display illumination flashes and Fault appears on the standard display 30 04 2009 Tcol Tcylb 10 59 47 7 C 35 4 C Fault Press the following keys 1 for the Main menu 2 for Messages 3 OK to confirm 4 for causes of the current fault 5 Make a note of the cause of the fault This enables the heating contractor to be better pre...

Page 13: ...ly by your heating contractor The function of the sacrificial anode can be checked without interrupting the sys tem operation The heating contractor will check the earth current with an anode tester Safety valve DHW cylinder The function of the safety valve must be checked every six months by the user or a contractor through venting see valve manufacturer s instructions The valve seat may become c...

Page 14: ...s or lines of the appliance or exter nally installed accessories these must be replaced with special cables or lines Only use Viessmann cables lines as replacement For this notify your quali fied contractor Upkeep Damaged cables lines 5608 437 GB ...

Page 15: ... from the examples illustrated here Main menu Actual values Reports Solar HM Manual mode Operator code Messages back No fault Interruption Sensor Sensor circuit Sensor Night circ ΔT too high Solar back Statement HM back HM 1 HM 2 Manual mode back All relays Relays 1 to 7 A A See page 7 Menu overview Menu overview 5608 437 GB ...

Page 16: ...nd local contractors on the internet under www viessmann com Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5608 437 GB Subject to technical modifications ...

Reviews: