44
Interval
Activity
System user
Heating con-
tractor
Before every heat-up
Check the ash chamber, clean if necessary.
X
Weekly
Clean the ash chamber.
X
After 100 hours run
Clean the tubular heat exchanger.
X
Check the fill level of the tubular heat exchanger ash pan,
empty the container if required.
X
After 300 hours run
Clean the sight glass.
X
Check the combustion chamber for deposits, clean if neces-
sary.
X
After 900 hours run, and at least once a year
Clean and calibrate the Lambda probe.
X
Clean the flue gas fan.
X
Check all gaskets for damage; replace if required.
X
Check the thermally activated safety valve for tightness.
X
Twice yearly
Thoroughly clean the boiler.
X
Every 5 years
Replace the battery inside the control unit.
X
Tasks for heating contractors
See installation and service instructions
Cleaning the ash chamber
A
B
C
Fig. 34
A
Ash pan
B
Ash chamber
C
Ash chamber door
1.
Pivot the ash box door up.
2.
Check the gaskets for wear and damage. Replace
these if required.
Maintenance
Maintenance intervals
(cont.)
5684 987 GB