116
Rated voltage:
230 V~
Rated frequency: 50 Hz
Rated current:
6.0 A
Safety class:
I
Protection:
IP X 4 D to
EN 60529
Permissible ambient temperature
■ during operation:
0 to +40
°
C
■ during storage and
transport:
-20 to +65
°
C
Electronic tempera-
ture limiter setting:
82
°
C (fixed)
Temperature limiter
setting:
100
°
C (fixed)
Line fuse (mains):
max. 16 A
Gas fired boiler, category II
2N3P
Rated output range
T
V
/T
R
50/30
°
C
kW
17 - 45
17 - 60
Rated thermal load range
kW
16.1 - 42.2
16.1 - 56.2
Power consumption (max.)
W
30
50
Connection values
in relation to the max. load
with
Natural gas E
m
3
/h
4.47
5.95
Natural gas LL
m
3
/h
5.19
6.91
LPG
kg/h
3.30
4.39
Product ID
_
-0085 BR 0432
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of factory
settings, the gas pressure must not be altered from these settings. Reference: 15
°
C,
1013 mbar.