52/53
Vitodens technical specification
Vitodens 100-W
Appliance
System
Combination
Model
Unit
19
26
30
35
26
30
35
Rated CH output
At Tf/Tr 50/30 °C (condensing)
kW
7.4 - 19
7.4 - 26.0
8.8 - 30.0
8.8 - 35.0
7.4 - 26.0
8.8 - 30.0
8.8 - 35.0
At Tf/Tr 80/60 °C (non-condensing)
kW
6.7 - 17.3
6.7 - 23.7
8.0 - 26.6
8.0 - 31.9
6.7 - 23.7
8.0 - 26.6
8.0 - 35.0
Rated central heating input (net)
kW
6.9 - 17.8
6.9 - 24.3
8.2 - 27.9
8.2 - 32.7
6.9 - 24.3
8.2 - 27.9
8.2 - 32.7
Rated central heating input (gross)
kW
7.7 - 19.8
7.7 - 27.0
9.1 - 30.9
9.1 - 36.4
7.7 - 27.0
9.1 - 30.9
9.1 - 36.4
Domestic hot water output range
kW
n/a
n/a
n/a
n/a
6.7 - 29.3
8.0 - 30.0
8.0 - 35.0
Max. natural gas rate (CH mode)
m3/h
1.9
2.6
3
3.5
2.6
3
3.5
Max. LPG
kg/H
1.4
1.9
2.2
2.6
1.9
2.2
2.6
Gas supply pressure
Natural gas
20
20
20
20
20
20
20
LPG
37
37
37
37
37
37
37
Max permissibe gas supply pressure
Natural gas
25
25
25
25
25
25
25
LPG
45
45
45
45
45
45
45
Efficiency/Emissions
Full load 100%
%
88.2
88.3
88.3
88.2
88.3
88.3
88.2
Part load 30%
%
97.9
97.9
97.5
98.5
97.9
97.5
98.5
Seasonal efficiency (SEDBUK)
%
90.3
90.3
90.4
90.3
90.2
90.3
90.2
SEDBUK rating
A
A
A
A
A
A
A
NOx classification
class
5 (<39 mg/kWh)
DHW/CH
DHW performance @ 35°C temp. rise
l/min
n/a
n/a
n/a
n/a
10
12
14
DHW temp. range
°C
n/a
n/a
n/a
n/a
30-60
30-60
30-60
Max. mains water inlet pressure
bar
n/a
n/a
n/a
n/a
10
10
10
Min. mains water inlet pressure
for max. DHW heat output
bar
n/a
n/a
n/a
n/a
0.5
0.5
0.5
Min. mains water inlet pressure
for operation
bar
n/a
n/a
n/a
n/a
0.5
0.5
0.5
Min. DHW flow rate for operation
l/min
n/a
n/a
n/a
n/a
0.5
0.5
0.5
Min. CH system pressure - cold
bar
0.5
0.5
0.5
0.5
0.5
0.5
0.5
Max. CH system pressure - hot
bar
3
3
3
3
3
3
3
Cylinder Capacity
l
n/a
n/a
n/a
n/a
n/a
n/a
n/a
CH flow temp. range
°C
30-80
30-80
30-80
30-80
30-80
30-80
30-80
General specification
Integral expansion vessel capacity
ltr
8
8
8
8
8
8
8
Integral expansion vessel pre-charge pressure
bar
0.75
0.75
0.75
0.75
0.75
0.75
0.75
Total water capacity
ltr
2.8
2.8
3.4
3.4
2.8
3.4
3.4
Lift weight
kg
35
36
37
37
36
38
38
Total weight (including packaging)
kg
37
38
39
39
38
40
40
Electricity supply
230v 50 HZ
230v 50 HZ
230v 50 HZ
230v 50 HZ
230v 50 HZ
230v 50 HZ
230v 50 HZ
Internal fuse
A
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Max power consumption
W
102
107
106
154
119
134
154
Water protect rating
IP X4D
IP X4D
IP X4D
IP X4D
IP X4D
IP X4D
IP X4D
Flue temp. @ 50/30 - max. CH output
°C
45
45
45
45
45
45
45
Flue temp. @ 50/30 - min. CH output
°C
35
35
35
35
35
35
35
Flue temp. @ 80/60 - max CH output
°C
68
68
68
69
68
68
70
Flue products mass flow rate - NG - max. CH output
kg/h
30.1
41.1
49
56.9
41.1
49
56.9
Flue products mass flow rate - NG - min CH output
kg/h
14.6
14.6
17.6
17.6
14.6
17.6
17.6
Flue products mass flow rate - LPG - max CH output
kg/h
34
46.4
54
62
46.4
54
62
Flue products mass flow rate - LPG - min CH output
kg/h
15.9
15.9
19.4
19.4
15.9
19.4
19.4
Max. gas pressure NG
mbar
20.25
20.25
20.25
20.25
20.25
20.25
20.25
Gas Council number
41-819-26
41-819-27
41-819-28
41-819-29
47-819-20
47-819-21
47-819-22
Product ID
CE-0085 BT0029
Dimensions/Connections
Inner flue duct diameter
mm
60
60
60
60
60
60
60
Outer flue duct diameter
mm
100
100
100
100
100
100
100
Boiler dimensions (height x width x depth)
mm
700 x 400 x 350
DHW outlet and mains cold inlet
mm
n/a
n/a
n/a
n/a
15
15
15
CH flow and return
mm
22
22
22
22
22
22
22
Condensate
mm
22
22
22
22
22
22
22
Gas
mm
22
22
22
22
22
22
22
PRV outlet
mm
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Max. horizontal flue length
m
19
13.5
13.5
17
13.5
13.5
17
Max. vertical flue length
m
19
13.5
13.5
17
13.5
13.5
17
Summary of Contents for Vitocell 200-B
Page 48: ...Training ...