190
This setting determines the maximum
output (stage 1, 2 or 3) of the instanta-
neous heating water heaters, with which
DHW or system heating is carried out.
In some cases, the output stages avail-
able depend on the type of power con-
nection.
"1"
Output stage 1, e.g. 3 kW
"2"
Output stage 2, e.g. 6 kW
"3"
Output stage 3, or subject to type
and power connection, stage 1
and 2 simultaneously, e.g. 9 kW
Menu
■
"Device settings"
■
"Programming"
■
"Electric heater"
■
"Max. stage E heat"
Delivered condition
3
Setting
1 / 2 / 3
Stage at power-OFF
Maximum output stage of the instantaneous heating water heater (accessory) during
the power-OFF.
The selected stage and all those below
it will be enabled.
"0"
Instantaneous heating water
heater remains off during power-
OFF, except for frost protection.
"1"
Output stage 1, e.g. 3 kW
"2"
Output stage 2, e.g. 6 kW
"3"
Output stage 3, or subject to type
and power connection, stage 1
and 2 simultaneously, e.g. 9 kW
Menu
■
"Device settings"
■
"Programming"
■
"Electric heater"
■
"Stage at power-OFF"
Delivered condition
0
Setting
0 / 1 / 2 / 3
Control settings, electric heater
Maximum stage, electric booster heater
(cont.)
5414 828 GB
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...