17
E
Power cable for compressor/fan
(400 V/50 Hz; 3/N/PE)
Recommended cable: 5 x 2.5 mm
2
F
Power cable for instantaneous heat-
ing water heater
(400 V/50 Hz; 3/N/PE; max. output
9 kW)
Recommended cable: 5 x 2.5 mm
2
G
Instantaneous heating water heater
(accessory)
H
Control panel
K
Heat pump type AWH-I
Required cable lengths:
■ For the heat pump control unit from the
wall outlet:
0.7 m
■ Inside the heat pump (to the control
panel):
3.4 m plus wall clearance for cable
entry from the left
3.4 m plus wall clearance minus appli-
ance width for cable entry from the
right
External heat pump type AWH-O
!
Please note
Avoid damaging the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
!
Please note
Installing a compressor at a steep
angle inside the heat pump can
result in equipment damage.
Never tilt the heat pump more
than 45° during handling and
installation.
Preparing for installation
Internal heat pump, type AWH-I
(cont.)
5414 828 GB
Installation
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...