Draining the heat pump on the secondary side
1.
Close on-site drain & fill valve.
2.
Drain heat pump at secondary flow
drain valve.
Checking sensors
For sensor connections to PCB 3 see
page 212.
For the position of the sensors in the heat
pump, see figure on page 165.
Temperature sensors type Ni 500
400
-40 -20
0
Resistance in
Temperature in °C
440
480
520
560
600
20 40 60
640
Capturing element: "Ni 500"
■ Outside temperature sensor (F0)
■ Flow temperature sensors, heating cir-
cuits M2, M3 (F12)
■ Room temperature sensors (Vitotrol)
Troubleshooting
Repairs
(cont.)
5414 828 GB