112
C
B
A
≈
F
H
5
4
3
4
4
3
3/N
3/N
G
K
4
kWh
kWh
3
E
D
1X3.7
1X3.6
Shown excluding fuses and RCD
A
Heat pump control unit
B
Instantaneous heating water heater
(accessory)
C
Compressor
D
Power supply to heat pump control
unit
E
Heating system main isolator
F
High tariff meter
G
Ripple control receiver (contact
open: power-OFF enabled)
H
Low tariff meter
K
TNC system feed
Phase monitor
The phase monitor is used to monitor the
mains power supply to the compressor.
The following different mains supplies (if
adjustable) are permissible in the deliv-
ered condition:
Over/undervoltage
15 %
Phase asymmetry
15 %
Switching delay
4 s
Installation sequence
Power supply
(cont.)
5414 828 GB