114
Pump/component
Parameter
Setting
Heating circuit pump and
mixer M2/HC2
"System definition"
Ó
"System scheme 7000"
With heating circuit
with mixer M2/HC2
Heating circuit pump and
mixer M3/HC3 (control via
extension kit for one heating
circuit with mixer)
"System definition"
Ó
"System scheme 7000"
With heating circuit
with mixer M3/HC3
Note
Set rotary selector S1
in the extension kit to
"2" (see extension kit
installation instruc-
tions).
Circulation pump for cylinder
heating (only for type AWO-
M-AC 301.A)
"System definition"
Ó
"System scheme 7000"
With DHW heating
"Internal hydraulics"
Ó
"Enable 3-way diverter
valve heating/DHW 730D"
"0"
3-way diverter valve for "Cen-
tral heating/DHW heating"
(only for type AWCI-M-AC
301.A)
"System definition"
Ó
"System scheme 7000"
With DHW heating
"Internal hydraulics"
Ó
"Enable 3-way diverter
valve heating/DHW 730D"
"1"
DHW heating
with primary store system:
■ Cylinder primary pump
■ 2-way shut-off valve
"System definition"
Ó
"System scheme 7000"
With DHW heating
"External heat source"
Ó
"Enable external heat
source for DHW heating
7B0D"
"1"
DHW circulation pump
Extended menu:
"Time prog. DHW circ."
Setting a time pro-
gram
Solar thermal system
"Solar"
Ó
"Type solar control unit
7A00"
■
"1"
(with Vitosolic
100)
■
"2"
(with Vitosolic
200)
Circulation pump for DHW
reheating
"External heat source"
Ó
"Enable external heat
source 7B00"
"1"
"External heat source"
Ó
"Enable external heat
source for DHW heating
7B0D"
"1"
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 875 GB
Summary of Contents for Vitocal 300 AWO-M-AC 301.A
Page 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Page 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Page 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Page 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Page 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Page 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...