71
Pumps and other components
Pump/component
Parameter
Setting
Heating circuit pump
"System definition"
Ó
"System scheme 7000"
■ With heating circuit A1/HC1
(for heating circuit without
mixer)
or
■ With heating circuit M2/HC2
(for heating circuit with mixer)
or
■ With heating circuit M3/HC3
(for heating circuit with mixer)
DHW circulation
pump
Extended menu:
"Time program DHW cir-
culation"
Set a time program.
Mixer extension kit for
heating circuit M3/
HC3
"System definition"
Ó
"System scheme 7000"
With heating circuit M3/HC3
Note
Set rotary switch S1 in the ex-
tension kit to "2": See extension
kit installation instructions.
Remote control for
heating/cooling circuit
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
or
"Heating circuit 3"
Ó
"Remote control 4003"
"1"
Note
Set heating circuit assignment
on the Vitotrol:
H1/HC1: For heating circuit 1
H2/HC2: For heating circuit 2
H3/HC3: For heating circuit 3
See "Vitotrol" installation in-
structions.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5516 436 GB
Service