56
!
Please note
If a casing door is not securely closed this can
lead to damage from condensation, vibrations
and excessive noise.
■
Seal the appliance so it is soundproof and dif-
fusion-proof.
■
On pipe and hose outlets, ensure the thermal
insulation is seated correctly.
Danger
The absence of system component earthing can
lead to serious injury from electrical current and
component damage in the event of an electrical
fault.
Attach earth conductor to front panel and side
panel.
Fitting the front panels of the indoor unit
5.
4.
2.
1.
3.
Fig. 50
4.
Ensure that the locking screw is tightened before
operating.
Installation sequence
Closing the heat pump
5831412
Installation