142
Type AWOT-M-E/AWOT-M-E-AC
221.A04
221.A06
221.A08
221.A10
221.A13
221.A16
Secondary circuit connec-
tions
(with connection accesso-
ries, female thread)
Heating water flow
G
1
¼
1
¼
1
¼
1
¼
1
¼
1
¼
Heating water return
G
1
¼
1
¼
1
¼
1
¼
1
¼
1
¼
DHW
G
¾
¾
¾
¾
¾
¾
Cold water
G
¾
¾
¾
¾
¾
¾
DHW circulation
G
¾
¾
¾
¾
¾
¾
Outdoor unit flow (heating water
outlet)
G
1
¼
1
¼
1
¼
1
¼
1
¼
1
¼
Outdoor unit return (heating wa-
ter inlet)
G
1
¼
1
¼
1
¼
1
¼
1
¼
1
¼
Length of connecting cable, in-
door unit
—
outdoor unit
m
1 to 20
1 to 20
1 to 20
1 to 20
1 to 20
1 to 20
Sound power of outdoor unit
at rated heating output
(Measurements with reference
to EN 12102/EN ISO 9614-2)
Weighted total sound power
level
■
At A7
±
3 K
/W55
±
5 K
(max.)
dB(A)
56
56
58
60
61
61
■
At A7
±
3 K
/W55
±
5 K
in night
mode
dB(A)
50
50
50
55
55
55
Energy efficiency class
to EU
Regulation no. 813/2013
Heating, average climatic con-
ditions
■
Low temperature applications
(W35)
A
++
A
++
A
++
A
++
A
++
A
++
■
Medium temperature applica-
tions (W55)
A
+
A
++
A
++
A
++
A
++
A
++
DHW heating, draw-off profile
(L)
A
A
A
A
A
A
Performance data
as per EU
Regulation no. 813/2013 (aver-
age climatic conditions)
Low temperature applications
(W35)
■
Energy efficiency
η
S
%
173
172
175
176
175
175
■
Rated heating output P
rated
kW
5.38
5.59
6.82
9.32
9.99
10.61
■
Seasonal coefficient of per-
formance (SCOP)
4.40
4.38
4.46
4.47
4.46
4.46
Medium temperature applica-
tions (W55)
■
Energy efficiency
η
S
%
124
125
127
129
130
130
■
Rated heating output P
rated
kW
5.23
5.59
6.41
9.35
10.07
10.72
■
Seasonal coefficient of per-
formance (SCOP)
3.18
3.21
3.25
3.29
3.32
3.34
■
DHW heating energy efficien-
cy
η
wh
%
119
119
119
117
117
117
Specification
Specification
(cont.)
5831412
Appendix