Type AWOT-E/AWOT-E-AC
221.A10
221.A13
221.A16
Heating performance data
to EN 14511 (A35/W7)
Rated cooling capacity
kW
5.00
6.00
7.00
Fan speed
rpm
600
600
600
Power consumption
kW
1.90
2.30
2.80
Energy efficiency ratio EER in cooling mode
2.70
2.60
2.50
Output control
kW
Up to 8.00
Up to 9.00
Up to 10.00
Heating performance data
to EN 14511 (A35/W18)
Rated cooling capacity
kW
7.00
8.20
9.20
Fan speed
rpm
600
600
600
Power consumption
kW
1.71
2.00
2.30
Energy efficiency ratio EER in cooling mode
4.10
4.10
4.00
Output control
kW
Up to 8.00
Up to 9.00
Up to 10.00
Air intake temperature
Cooling mode (type AWOT-E-AC only)
– Min.
°C
10
10
10
– Max.
°C
45
45
45
Heating mode
– Min.
°C
–20
–20
–20
– Max.
°C
35
35
35
Heating water
(secondary circuit)
Minimum flow rate
l/h
1550
1550
1550
Minimum volume in the heating system, cannot be fitted
with shut-off devices
l
50/40
*8
50/40
*8
50/40
*8
Max. external pressure drop (RFH) at minimum flow rate
mbar
400
400
400
kPa
40
40
40
Max. flow temperature
°C
60
60
60
Outdoor unit electrical values
Rated voltage, compressor
3/N/PE 400 V/50 Hz
Max. operating current, compressor
A
8.7
8.7
8.7
Cos φ
0.96
0.96
0.96
Starting current, compressor
A
15
15
15
Fuse rating
A
16
16
16
IP rating
IP X4
IP X4
IP X4
Indoor unit electrical values
Heat pump control unit/PCB
– Rated voltage, control unit/PCB
1/N/PE 230 V/50 Hz
– Power supply fuse rating
1 x B16A
1 x B16 A
1 x B16 A
– Internal fuse
6.3 A (slow)/250 V
Instantaneous heating water heater
– Rated voltage
1/N/PE 230 V/50 Hz
or
3/N/PE 400 V/50 Hz
– Heating output
kW
9
9
9
– Power supply fuse rating
3 x B16A
3 x B16 A
3 x B16 A
Max. power consumption
Fan
W
2 x 45
2 x 45
2 x 45
Outdoor unit
kW
5.13
5.13
5.15
Secondary pump (PWM)
W
60
60
60
– Energy efficiency index EEI
≤ 0.2
≤ 0.2
≤ 0.2
Control unit/PCB, outdoor unit
W
15
15
15
Control unit/PCB, indoor unit
W
10
10
10
Control unit/PCB power, indoor unit
W
1000
1000
1000
Refrigerant circuit
Refrigerant
R410A
R410A
R410A
– Refrigerant charge
kg
2.40
2.40
2.40
– Global warming potential (GWP)
*9
1924
1924
1924
– CO
2
equivalent
t
4.6
4.6
4.6
Compressor (hermetically sealed)
Type
Scroll
Scroll
Scroll
– Oil in compressor
Type
3 MAF POE
3 MAF POE
3 MAF POE
– Quantity of oil in compressor
l
1.17
1.17
1.17
Permissible operating pressure
– High pressure side
bar
43
43
43
MPa
4.3
4.3
4.3
– Low pressure side
bar
28
28
28
MPa
2.8
2.8
2.8
*8
When using the heating water buffer cylinder Vitocell 100-E, type SVPA, part no. ZK03801 in the secondary circuit return
*9
Based on the Fifth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC)
Vitocal 222-A
(cont.)
VITOCAL
VIESMANN
21
5831388
3