For connections to the DHW heat pump, see pages 9
and 21.
Fitting the temperature sensor
!
Please note
Damage to the connecting cables and sensor
leads (capillaries) causes malfunctions.
■
The connecting cables and sensor leads must
not come into contact with hot components.
When routing and securing connecting cables
and sensor leads, ensure that the maximum
permissible temperatures for these cables/
leads are not exceeded.
■
Never kink the capillary tubes.
2.
4.
3.
5.
1.
Fig. 17
Adjusting the draw-off rate
If there is high demand for DHW, it is possible to
change the draw-off profile from L to XL. To do this, the
cylinder temperature sensor fitted at the factory is
removed from sensor well
A
and fitted in sensor well
B
.
Note
The high limit safety cut-out for the DHW heat pump
must also be refitted.
Installation sequence
Type WWKS: external heat generator