23
Fitting the cylinder temperature sensor
Note
The cylinder temperature sensor is supplied in the con-
trol unit pack.
3.
4.
1.
2.
C
C
AB
AB
B
C
C
Fig. 20
A
Sensor wells for 200 l capacity
B
Sensor wells for 400 l capacity
C
Sensor wells for 750 and 950 l capacity
Note
■
Never
wrap insulating tape around the sensor.
■
Secure the sensor to the
outside
of the sensor
retainer contact spring (not in the groove) so that it is
flush with the front of the spring.
■
Insert the sensor retainer with sensor as far as possi-
ble into the sensor well.
Connections on the heating water side
Any number of heating water buffer cylinders, type
SVPA, can be connected in series or in parallel. The
connecting pipes and air vent valves must be provided
on site.
!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
Installation sequence
Fitting the Vitotrans and thermal insulation,…
(cont.)
5517 175 GB
Installation