background image

 

 

01.02.2021

 

Cod. 80006610a - GB - VR

 

Read carefully and keep for future reference  

DOC. 1 di 2

 

USER MANUAL

 

Tecto CI4

 

 

Summary of Contents for GALILEI Tecto CI4

Page 1: ...01 02 2021 Cod 80006610a GB VR Read carefully and keep for future reference DOC 1 di 2 USER MANUAL Tecto CI4...

Page 2: ...s The warnings included in this manual have been categorized as follows WARNING information for the correct and effective use of the unit DANGER notices relevant to potential hazards for people ATTENT...

Page 3: ...rtation and handling 14 4 2 Reception and storage 14 5 Setting up the unit 15 5 1 Positioning the refrigerated cabinet 15 5 2 Unpacking 16 5 3 Feet supports adjusting 16 5 4 Cleaning before starting 1...

Page 4: ...8 6 Defrosting 27 8 7 Lights switching on off 27 8 8 Alarm warnings 28 8 9 Programming the controller 29 9 Wurm CRA control panel 30 9 1 Description 30 9 2 Switch the unit on and off 30 9 3 Normal con...

Page 5: ...s Caution Do not obstruct the ventilation openings along the external perimeter of the unit Caution In case the cable or the plug are damaged call the maintenance personnel for the replacement 1 2 Gen...

Page 6: ...rcuit again with inert gas Open the circuit and carry out the maintenance 1 3 Residual hazards Residual hazards are risks that remain even after all possible protection measures are taken in the desig...

Page 7: ...n have a reduced perception of danger If they are not supervised children might be at risk Do not allow chil dren to play or run near the refrigerating cabinet Do not allow them to climb on or hang fr...

Page 8: ...superstructure It is suitable for the displaying and selling of meat fish i e Fish ver sion salami milk and dairy products deli meat and produce Including endwalls display decks of powder coated galva...

Page 9: ...9 01 02 2021 Cod 80006640a GB VR 2 3 Cross sections ____________________________________________ 2 General data and features Tecto CI4 90 VC Tecto CI4 90 VC FISH Tecto CI4 90 VD Tecto CI4 90 VD FISH...

Page 10: ...10 01 02 2021 Cod 80006640a GB VR 2 4 Front Views ______________________________________________ 2 General data and features Tecto CI4 90 VC Tecto CI4 90 VD...

Page 11: ...itions temperature and humidi ty in the store and the cleanliness of the condenser Our tests recorded a maximum noise level of 54 dB A at a dis tance of 1 m from the cabinet 2 7 Weight of the refriger...

Page 12: ...it proper ly 3 Rating plate RoHS The refrigerated cabinet is subject the WEE European Direc ve 2002 96 EC for plug in refrigerated cabinets only The unit complies with the RoHS European Direc ve 2002...

Page 13: ...were built given by the temperature class 7 Power absorbed during defrost includes the electric heater if present and all the other electric devices operat ing during the defrost cycle such as contro...

Page 14: ...safety shoes Only when the cabinet is placed on the final point of installation inside the market remove the protecting film and plates For this operation refer to chapter 5 2 Unpacking The packaging...

Page 15: ...om temperature of 25 C R H 60 Higher levels of temperature and or relative humidity can cause higher energy consumptions and poor er performances consequently shortening the shelf life of the displaye...

Page 16: ...s Proceed with caution and do not cut the strings while standing in front of them Packaging is mostly made of recyclable materials wood and cardboard and small amounts of plastic film Do not dispose o...

Page 17: ...ce limits 10 It is mandatory to ground the refrigerated cabinet Efficient grounding is essential for safety Upstream of the socket it is recommended to have the installation of an omni polar power iso...

Page 18: ...o a cold room to re establish the ideal temperature The working temperature of the refrigerated cabinet is displayed by the digital thermometer installed in the cabinet usually it is close to the air...

Page 19: ...prevents air from circulating properly If there is massive or a rapidly developed for mation of frost inside the evaporator that requires frequent manual defrost operations it means that the environm...

Page 20: ...he glass parts Use suitable PPE Turn the unit into a Self Service version Rotate the acrylic glass top canopy 2 if any towards the back shelf Fig 1 Completely remove the upper glass 3 and make it slid...

Page 21: ...intenance calendar ______________________________ The proper maintenance will guarantee the optimal functioning of the refrigerated cabinet and consequently a reduc tion of energy consumption and long...

Page 22: ...x 35 C If there are halos add some neutral diluted detergent pH 6 8 Rinse and dry with a soft and dry cloth Do not use corrosive deter gents thinners alcohol or solvents For cleaning completely the ac...

Page 23: ..._______________________________ Use a soft and non abrasive cloth with neutral de tergents pH 6 8 for cleaning and a soft and dry cloth for drying Do not use abrasive products or metal scrapers that m...

Page 24: ...m fins of the condenser can cause injuries to hands and arms use protective gloves for cleaning these parts For the filter removal perform the following steps Open the panel 1 by inserting the supplie...

Page 25: ...switch on the refrigerated cabinet and enable its functions turn on the main magnetothermal switch from the con trol panel When the unit is on the display will show all icons and the 3 digit panel fo...

Page 26: ...echnical reasons the temperature values provided by the two displays i e ther mometer in the refrigerated cabinet and controller display even if related to one another could be different and vary duri...

Page 27: ...and it depends on the temperature detected by a specific sensor positioned inside the evaporator defrost sensor This sensor enables the end of the defrost unless the maximum safety duration time i e t...

Page 28: ...e loading conditions of the displayed products refer to Chapter 6 Loading and using the cabinet Remove the products and store them in an suitable refrigerated place i e cold rooms another refrigerated...

Page 29: ...using ARROWS UP DOWN Press the SET key to display the parameter value Use the ARROWS UP DOWN to change the parameter value To exit the programming mode press SET UP ARROW or wait for 15 second without...

Page 30: ...the unit off and on 9 2 Switch the unit off and on__________________________________________ To switch on the cabinet and enable its functions turn on the main magnetothermal switch When it is switche...

Page 31: ...of the unit If it is necessary repeat the operation until achieving the desired temperature 9 4 User interface ___________________________________________________ Each key 1 has a two functions Briefl...

Page 32: ...e temperature detected by a specific sensor placed inside the evaporator i e the defrost sensor This sensor determines the end of the defrost unless the maximum preset time is reached time out Manual...

Page 33: ...lace i e cold rooms another refrigerated cabinet if it is nec essary Warning AH This warning indicates high temperature for preserving the displayed products Check the temperature with the digital the...

Page 34: ...rd which is set at the factory password 19 Push the key for 4 seconds and the message PA will be shown on the display Push the key again and enter the password by using the and keys To confirm the pas...

Page 35: ...ervention of the magnetothermal isolator switch Reset the isolator switch If the problem isn t solved turn off the refrigerated cabinet and call The refrigerated cabinet does not refrigerate properly...

Page 36: ...me models Refrigerated cabinet in defrosting phase Wait for the end of defrosting phase See 8 6 defrosting Presence of water on the floor Presence of condensa tion on the cabinet Products not loaded c...

Page 37: ...g relays defrost heaters temperature sensors light sources door handles and door hinges knobs and buttons door gaskets and display decks 11 2 Warranty The faulty parts are covered by the warranty for...

Page 38: ...igerant gases For refrigerated cabinets which work with flammable HC R290 refrigerant refer to the safety provisions given in the chapter For your safety at the beginning of this manual After the remo...

Page 39: ...orter des modifications tout moment sans aucun pr avis et sans encourir d obligations Galilei Refrigerazione S r l se reserva el derecho de cambiar este documento en cualquier momento sin previo aviso...

Page 40: ...GALILEI REFRIGERAZIONE S R L VIA VENETO 29 31 35020 DUE CARRARE PD ITALY Tel 39 049 99 30 650 Fax 39 049 52 11 341 WWW GALILEISPA IT...

Reviews: