31
L1
B
F
E
D
D
N
C
A
40
A
Power supply for extension (elec-
tronics module)
B
Power supply for heat generator
C
Power supply 1/N/PE, 230 V/50 Hz
D
Fuse (max. 16 A)
E
Mains isolator, 2-pole, on site
F
Junction box (on site)
Connect the power supply in accord-
ance with the diagram.
If the power supply to the appliance is
connected with a flexible power cable,
ensure that the live conductors are
pulled taut before the earth conductor
in the event of strain relief failure. The
length of the earth conductor wire will
depend on the design.
Danger
Incorrect core assignment can
result in serious injury and dam-
age to the appliance.
Never interchange cores "L" and
"N".
!
Please note
Incorrect phase sequence can
cause damage to the appliance.
Ensure phase equality with the
heat generator power supply.
Colour coding to IEC 60757
BN
Brown
BU
Blue
GNYE Green/yellow
Extension kit with mixer PCB
(cont.)
5836498