112
Changing the rotational direction of the mixer motor (if required)
gS
BU
|
~
Fig. 71
1.
Remove the top casing cover of the extension kit.
Danger
An electric shock can be life threatening.
Before opening the boiler, disconnect it from
the mains voltage, e.g. at the fuse or mains
isolator.
2.
At plug
gS
, swap the cores at terminals "
|
" and
"
~
".
3.
Refit the casing cover.
Checking the Vitotronic 200-H (accessories)
The Vitotronic 200-H is connected to the control unit
via the LON cable. To test the connection, conduct a
subscriber check at the heat source control unit (see
page 60).
Maintenance
Mixer extension kit
(cont.)
5678 044 GB
Maintenance