66
Yes
Automatic calibration of
the combustion controller
No
Fault E3
Ensure adequate heat trans-
fer. Press reset button
R
.
Fault Eb
Check gap between ionisa-
tion electrode and burner
gauze assembly.
Check allocation of gas type
(coding address 82, gas train
setting).
Check flue system; remedy
flue gas recirculation if re-
quired.
Press reset button
R
.
For further details regarding faults, see page 115.
Preparing the fuel cell module for commissioning
Checking the power supply
A
Fig. 65
1.
Check that the power supply has been connected
according to the details on page 39.
2.
Removing the front panel (if it is still attached); see
page 52.
3.
Ensure that ON/OFF switch
A
on the fuel cell
module is switched OFF (
0
).
4.
Switch on the power supply at the sub-distribution
board.
Programming unit on the fuel cell module
All settings for commissioning and maintenance are
made using the programming unit on the fuel cell mod-
ule.