76
Sensor
Capturing ele-
ment
■ Outside temperature sensor (F0)
■ Flow temperature sensor, cooling circuit (direct heating circuit
A1/HC1 or separate cooling circuit SKK) (F14)
■ Room temperature sensors
Ni 500
■ Buffer temperature sensor (F4)
■ Cylinder temperature sensor (F6)
■ Flow/return temperature sensor, secondary circuit (F8/F9)
■ System flow temperature sensor (F13)
■ Return temperature sensor, solar circuit (F18)
■ Collector temperature sensor (F21)
■ Flow temperature sensor, secondary circuit, upstream of the
instantaneous heating water heater
■ Hot gas temperature sensor
Pt 500
Temperature sensors type Ni 500
400
-40 -20
0
Resistance in
Temperature in °C
440
480
520
560
600
20 40 60
640
Temperature sensors type Pt 500
460
20
540
100
Resistance in
Temperature in °C
60
140 180
620
700
780
860
-20
Checking the fuses
For fuse locations, see from page 34:
■ Fuse F1 is located near the luster ter-
minals.
■ Fuse F3 is located on the main PCB.
Fuses F1 and F3:
■ 6.3 A (slow), 250 V~
■ Max. power loss
≤
2.5 W
Troubleshooting
Repairs
(cont.)
5601 598 GB
Summary of Contents for BWT 241.A Series
Page 20: ...20 aCH 11 10 193C SLP N 224 6 9 Installation sequence Siting the heat pump cont 5601 598 GB...
Page 22: ...22 4x 4x 6x 2x 22 19 21 20 Installation sequence Siting the heat pump cont 5601 598 GB...
Page 23: ...23 4x 23 2x 26 25 24 Installation sequence Siting the heat pump cont 5601 598 GB Installation...
Page 27: ...27 C D BB Installation sequence Siting the heat pump cont 5601 598 GB Installation...
Page 71: ...71 Opening programming unit 2 2x 1 3 Troubleshooting Repairs cont 5601 598 GB Service...
Page 123: ...123 5601 598 GB...