17
Minimum clearances
Minimum room height h
Installation
h in mm
■
Without
connection set for
pre-installation/DHW
(accessory)
2250
■
With
connection set for
pre-installation/DHW
(accessory)
2350
Observe design information.
Vitocal technical guide
Handling
During handling, the cylinder module can
be removed (see from page 18). In
addition, the heat pump module can be
removed (see page 24).
!
Please note
Prevent damage to the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
!
Please note
If the compressor is at a steep
angle in the heat pump, lubricant
will enter the refrigerant circuit
and damage the appliance.
Max. tilting angle 45°.
Installation sequence
Siting the heat pump
(cont.)
5601 598 GB
Installation