84
Plug
sXF
Terminals
Function
Explanation
224.6
M
■ Cylinder primary pump
(DHW side)
■ 2-way shut-off valve
Switch cylinder primary pump and two-
way shut-off valve in parallel
Connection values
■ Output: 130 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site.
224.7
Circulation pump for DHW
reheating
or
Immersion heater control
Connection values
■ Output: 100 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site.
Immersion heater (400 V~)
224.7
X2.N
N
L3
L2
L1
?
B
A
A
Immersion heater, power supply
3/N/PE 400 V/50 Hz
B
Terminals of the heat pump control
unit
Installation sequence
Electrical connections
(cont.)
5600 161 GB