7
BW 301.A17
148 kg
BWS 301.A17
144 kg
BWC 301.A17
158 kg
■ To prevent structure-borne noise,
never site the appliance on ceilings
with wooden joists (e.g. in the attic).
■ Level the appliance horizontally.
If the adjustable feet are used to com-
pensate for an uneven floor (max.
10 mm), the pressure load on the feet
must be distributed evenly.
■ Observe the required floor area and
minimum room volume (to
DIN EN 378).
Type
Min. space
requirement
BW 301.A06
BWS 301.A06
BWC 301.A06
3.5 m
3
BW 301.A08
BWS 301.A08
BWC 301.A08
4.3 m
3
BW 301.A10
BWS 301.A10
BWC 301.A10
5.5 m
3
BW 301.A13
BWS 301.A13
BWC 301.A13
5.9 m
3
BW 301.A17
BWS 301.A17
BWC 301.A17
8.0 m
3
■ Observe required minimum clearan-
ces:
Single stage (type BW 301.A, BWC
301.A)
≥ 400
≥ 1500
A
B
Preparing for installation
Installation
(cont.)
5600 161 GB
Installation
Summary of Contents for BW 01.A06
Page 121: ...121 Opening the shield Troubleshooting Repairs cont 5600 161 GB Service ...
Page 166: ...166 5600 161 GB ...
Page 167: ...167 5600 161 GB ...