![Viessmann BS2A Installation And Service Instructions For Contractors Download Page 22](http://html.mh-extra.com/html/viessmann/bs2a/bs2a_installation-and-service-instructions-for-contractors_1018130022.webp)
22
Latitude
Year-round use
Winter use
Positioning angle of collec-
tor
Positioning angle of collec-
tor
75°
90°
75°
90°
Angle of inclination of the absorbers
18°
63°
—
36°
—
20°
61°
—
33°
—
22°
58°
—
31°
—
24°
55°
—
30°
—
26°
52°
—
28°
—
28°
49°
—
26°
—
30°
44°
6°
25°
8°
32°
40°
6°
24°
9°
34°
34°
6°
23°
10°
36°
28°
6°
22°
11°
38°
25°
6°
20°
12°
40°
23°
6°
18°
12°
42°
22°
6°
16°
13°
44°
21°
6°
14°
14°
46°
21°
6°
12°
16°
48°
21°
7°
10°
17°
50°
21°
7°
9°
19°
52°
21°
8°
7°
19°
Installing the DHW cylinder
Do
not
install the DHW cylinder verti-
cally.
Installation sequence
Angle of inclination of the absorbers
5516 344 GB