86
Row (brief
scan)
Field
1
2
3
4
5
6
7:
LON
Subnet address/system num-
ber
LON
Node address
0
0
8:
LON
SNVT or
SVNT config-
uration
LON
Software ver-
sion, commu-
nication cop-
rocessor
LON
Software version, neuron chip
Number of LON subscribers
9:
Heating circuit A1/HC1
Heating circuit M2/HC2
Heating circuit M3/HC3
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A
Software ver-
sion, remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A
Software ver-
sion, remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A/
200-RF
2: Vitotrol
300-A
Software ver-
sion, remote
control
10:
0
0
0
0
0
0
11:
0
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M2
0: No mixer
extension
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M3
0: No mixer
extension
0
12:
Vitovent gateway
CU-ID
Connection error, Vitovent
0: Without
1: With
xx
xx
13:
0
0
0
0
0
0
14:
0
0
0
0
0
0
Checking outputs (actuator test)
Tap the following buttons:
1. "Menu"
2. "Service"
3.
Enter
"viservice"
password.
4. "Actuator test"
5.
Select actuator (tap).
6.
Deactivate actuator or select another actuator with
.
The actuator is also deactivated automatically after
30 min.
The following actuators (relay outputs) can be controlled subject to system design:
Display
Explanation
"All actuators"
"OFF"
All actuators are off
"Base load"
"ON"
Burner operates at min. output. Internal pump is switched on
"Full load"
"ON"
Burner operates at max. output. Internal pump is switched on
"Output 20"
"ON"
Internal output
sÖ
(int. pump) active
Diagnosis and service scans
Diagnosis
(cont.)
5778741
Diagnosis