Reconnect the DHW cylinder to the pipework.
2.
Insert a new gasket underneath the flange cover.
3.
Mount the flange cover and tighten the screws with
a maximum torque of 25 Nm.
4.
Push the earth cable onto the tab.
5.
Fit the cover.
6.
Fill the DHW cylinder with potable water.