![Viessmann B2HF Installation And Service Instructions For Contractors Download Page 59](http://html.mh-extra.com/html/viessmann/b2hf/b2hf_installation-and-service-instructions-for-contractors_1016821059.webp)
59
A
2.
4.
3.
Fig. 46
1.
Drain the boiler on the DHW side.
2.
Remove the spring clip.
3.
Remove the DHW flow sensor.
4.
Check flow limiter
A
. Replace in case of exces-
sive scaling or damage. Reinsert.
5.
Mount DHW flow sensor with new gaskets.
Danger
Risk of electric shock from escaping heating
water or DHW.
Check all water side connections for tight-
ness.
Flow limiter
Serial no.
(type plate)
Flow rate
l/min
Colour
7544719
12
Red
7544720
14
Pink
7745530
16
Blue
7745531
12
Red
7544721
14
Pink
7544722
16
Blue
Checking the expansion vessel and system pressure
Note
The burner control unit can be removed to allow better
access to the test connector:
■
Pull the burner control unit to the right at the top until
the hook and loop fastening comes apart.
■
Undo the catch and remove the burner control unit
from the retainer by lifting it upwards.
Note
The expansion vessel can lose some of its charge
pressure over time. When the boiler heats up, the
pressure rises to 2 or 3 bar (0.2 or 0.3 MPa). The
safety valve may also respond and discharge the
excess pressure.
Therefore check the expansion vessel pre-charge
pressure annually.
Check whether the installed expansion vessel is ade-
quate for the system water volume.
Carry out this test on a cold system.
1.
Drain the system until "0" is shown on the pressure
indicator.
2.
If the pre-charge pressure of the expansion vessel
is lower than the static system pressure: Top up
with nitrogen at the valve of the diaphragm expan-
sion vessel until the pre-charge pressure is 0.1 to
0.2 bar (10 to 20 kPa) higher than the static system
pressure.
Commissioning, inspection, maintenance
Checking the flow limiter (only for gas condensing combi boiler)
5593201
Summary of Contents for B2HF
Page 33: ...33 2 2x 1 Fig 26 Installation sequence Closing the wiring chamber 5593201 Installation ...
Page 111: ...111 1 2 4 3 6 5 Fig 56 Troubleshooting Repairs cont 5593201 Diagnosis ...
Page 134: ...134 WiFi router 31 Wiring diagram 121 Keyword index Keyword index cont 5593201 ...
Page 135: ...135 5593201 ...