149
Type AWT-AC
241.A04
241.A07
241.A10
241.A13
Connections
Heating water flow
mm
Cu 28 x
1
Cu 28 x
1
Cu 28 x
1
Cu 28 x 1
Heating water return
mm
Cu 28 x
1
Cu 28 x
1
Cu 28 x
1
Cu 28 x 1
Cold water
Rp
¾
¾
¾
¾
DHW
Rp
¾
¾
¾
¾
DHW circulation
G
1
1
1
1
Solar circuit flow
DN 20 pipe sleeve for multi connect system
Solar circuit return
DN 20 pipe sleeve for multi connect system
Liquid line
■ Pipe
7
mm
6 x 1
10 x 1
10 x 1
10 x 1
■ Internal unit
UNF
⅝
⅝
⅝
⅝
■ External unit
UNF
⁷
⁄
₁₆
⅝
⅝
⅝
Hot gas line
■ Pipe
7
mm
12 x 1
16 x 1
16 x 1
16 x 1
■ Internal unit
UNF
⅞
⅞
⅞
⅞
■ External unit
UNF
¾
⅞
⅞
⅞
Max. line length, liquid line,
hot gas line
m
20
30
30
30
Sound power of external unit
at rat-
ed heating output
(measurements with reference to
EN 12102/EN ISO 9614-2)
Weighted total sound power level
■ At A7
±3 K
/W35
±5 K
dB(A)
60
62
62
63
■ At A7
±3 K
/W35
±5 K
in night
mode
dB(A)
58
58
60
60
Type AWT-AC
241.B10
241.B13
Heating output data
to EN 14511
(A2/W35)
Rated heating output
kW
7.57
9.06
Fan speed
rpm
600
690
Power consumption
kW
2.00
2.45
Coefficient of performance ε
(COP) in heating mode
3.79
3.70
Output control
kW
2.73 to 10.92
3.30 to 12.29
Specification
Specification
(cont.)
5546 699 GB
Service