142
400 V appliances
Type AWT-AC
221.B10
221.B13
Heating output data
At 100 % according to EN 14511
(A2/W35 °C, spread 5 K)
Rated heating output
kW
7.57
9.06
Compressor frequency
Hz
40
50
Fan speed
rpm
600
690
Power consumption
kW
2.99
2.45
Coefficient of performance ε (COP) in heat-
ing mode
3.79
3.70
Output control
kW
2.73 – 10.92
3.30 – 12.29
Heating output data
At 100 % according to EN 14511
(A7/W35 °C, spread 5 K)
Rated heating output
kW
10.16
12.07
Compressor frequency
Hz
40
50
Fan speed
rpm
600
690
Air flow rate
m
3
/h
3456
4217
Power consumption
kW
2.00
2.57
Coefficient of performance ε (COP) in heat-
ing mode
5.08
4.69
Cooling performance data
At 100 % according to EN 14511
(A35/W7 °C, spread 5 K)
Rated cooling capacity
kW
9.14
10.75
Compressor frequency
Hz
55
65
Fan speed
rpm
600
690
Power consumption
kW
3.37
4.15
Energy efficiency ratio EER
2.71
2.59
Output control
kW
1.96 – 9.85
2.14 – 11.45
Cooling performance data
At 100 % according to EN 14511
(A35/W18 °C, spread 5 K)
Rated cooling capacity
kW
8.83
12.83
Compressor frequency
Hz
35
55
Fan speed
rpm
600
690
Power consumption
kW
1.98
3.45
Energy efficiency ratio EER
4.46
3.72
Specification
Specification
(cont.)
5782 201 GB