76
Pumps and other components
Pump/component
Parameter
Setting
Heating circuit pump
"System definition"
Ó
"System scheme 7000"
■ With heating circuit A1/
HC1 (for heating circuit
without mixer)
or
■ With heating circuit M2/
HC2 (for heating circuit
with mixer)
or
■ With heating circuit M3/
HC3 (for heating circuit
with mixer)
Circulation pump for cyl-
inder heating
or
Cylinder loading pump
"System definition"
Ó
"System scheme 7000"
With DHW heating
DHW circulation pump
Extended menu:
"Time program DHW cir-
culation"
Set time program
Mixer extension kit for
heating circuit M3/HC3
"System definition"
Ó
"System scheme 7000"
With heating circuit M3/
HC3
Note
Set rotary switch S1 in the
extension kit to "2" (see ex-
tension kit installation in-
structions).
Remote control
For the heating/cooling cir-
cuit:
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
or
"Heating circuit 3"
Ó
"Remote control 4003"
"1"
Note
Set heating circuit assign-
ment on the Vitotrol (see
"Vitotrol" installation instruc-
tions).
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5546 267 GB