Double-tariff meter (for special tariff
for heat pump)
Not
permissible in conjunction with
PV systems for on-site power con-
sumption
H
Bi-directional meter (for PV systems
to consume power on site):
Energy taken from power supply
utility and energy fed into power
supply utility
K
Meter with reverse block:
For energy generated by PV sys-
tem
L
Isolator for the domestic power sup-
ply connection (distribution panel)
M
Distribution panel
N
Domestic distribution box
Phase monitor (if installed)
The phase monitor is used to monitor the
mains power supply to the compressor.
The phase monitor switches off (switch-
ing contact opens) if the tolerances set
in the phase monitor are exceeded.
The phase monitor automatically re-ena-
bles the power supply if the values return
to within the specified tolerance range.
Remove the cause if the relay has
responded. The relay does not need to
be reset.