Parameters for instantaneous heating water heater
Parameter
Setting
"Electr booster heater"
Ó
"Enable instantaneous heating water heater 7900"
"1"
"Output for instant. heating water heater at power-OFF 790A" "1"
3 kW
"2"
6 kW
"3"
9 kW
Enabling instantaneous heating water heater for DHW heating
"DHW"
Ó
"Enable electric heaters for DHW heating 6015"
"1"
Parameters for external heat source
Parameters
Setting
"External heat source"
Ó
"Enable external heat source 7B00"
"1"
Enable external heat source for DHW heating
"External heat source"
Ó
"Enable external heat source for DHW heating 7B0D"
"1"
Release circulation pump for DHW reheating
"External heat source"
Ó
"Enable booster heaters for DHW heating 6014"
"1"
Parameters for immersion heater
Parameters
Setting
"DHW"
Ó
"Enable electric heaters for DHW heating 6015"
"1"
"Enable booster heaters for DHW heating 6014"
"1"
Parameters for swimming pool water heating
Parameter
Setting
"System definition"
Ó
"External extension 7010"
"1"
or
"3"
"Swimming pool 7008"
"1"
Parameters for ventilation
Parameters
Setting
"Ventilation"
Ó
"Vitovent enable 7D00"
"1"
Vitovent 300-F
"2"
Vitovent 200-C
Commissioning, inspection, maintenance
Commissioning the system
(cont.)