Wall mounting
Installation must be completed with the
bracket set for wall mounting (acces-
sory).
Separate installation instructions
Note
Wind loads must be considered when
installing the unit on external walls or
roofs.
Installing the internal unit
!
Please note
Avoid damaging the appliance
during transportation.
Never
put weight on top of the
appliance.
Installation room requirements
!
Please note
The installation room must be dry
and free from the risk of frost.
Ensure ambient temperatures of
0 to 35 ºC.
!
Please note
Avoid dust, gases and vapours
due to a risk of explosion
in the installation room.
Minimum room volume (to
DIN EN 378):
Type AWB/AWB-
AC
Minimum room
volume in m
3
201.A04
2.7
201.A07
4.8
201.A10
6.7
201.A13
6.7