![Viessmann 7424689 Installation And Service Instructions Manual Download Page 123](http://html1.mh-extra.com/html/viessmann/7424689/7424689_installation-and-service-instructions-manual_1017806123.webp)
123
Type AWB/AWB-AC
201.A04
201.A07
201.A10
201.A13
Connections
Heating water flow
G
1¼
1¼
1¼
1¼
Heating water return
and DHW cylinder
return
G
1¼
1¼
1¼
1¼
DHW cylinder flow
G
1¼
1¼
1¼
1¼
Condensate line
(external unit)
mm
16 x 1
16 x 1
16 x 1
16 x 1
Liquid line
■ Pipe
7
mm
6 x 1
6 x 1
6 x 1
6 x 1
■ Internal unit
UNF
⅝
⅝
⅝
⅝
■ External unit
UNF
⁷
⁄
₁₆
⅝
⅝
⅝
Hot gas line
■ Pipe
7
mm
12 x 1
16 x 1
16 x 1
16 x 1
■ Internal unit
UNF
⅞
⅞
⅞
⅞
■ External unit
UNF
¾
⅞
⅞
⅞
Max. line length, liquid
line, hot gas line
m
20
30
30
30
Weighted total sound
power level
(test with reference to
DIN EN 12102/
DIN EN ISO 9614-2)
Weighted total sound
power level at A7 °C
(±3 K)/W35 °C (±5 K)
at rated heating output dB(A)
60
62
62
63