background image

3

GB

Technical Data

digital format: 

DCC and SELECTRIX

®

maximum current
 draw at motor output: 

appr. 1 A

 per light output: 

appr. 300 mA

 per function output F1 (horn): 

appr. 50 mA

total current: 

appr. 1 A

dimensions: 

appr. 13,8 x 9 x 1,8 mm

3

Auxiliary function

1. Introduction

The  locomotive  decoder  art.  no.  5252 / DHL  161  is 
most similar to the decoder art. no. 5254 / DHL 101. 
Supplementary to the DHL 101 the DHL 161 may 
be  additionally  used  for  DCC  controlled  layouts. 
Though  the  dimensions  could  be  reduced  again, 
so that the installation of the decoder in smaller lo-
comotives is much easier.
In  this  fact  the  enclosed  manual  for  the  decoder 
DHL  101  (5254)  is  valid  for  the  DHL  161  (5252). 
The differences between the two decoders and ad-
ditional hints you can fi nd on this manual.

2. Properties

Supplementary to the manual DHL 101 (5254) the 
following properties are only valid for the SELEC-
TRIX

®

 system:

•  block control with simple diodes
•  feedback of address for identification during 

operation

3. Operation

This decoder is intended for
•  analogue DC operation (automatic switching)
•  digital layouts using the DCC system
•  digital layouts using the SELECTRIX

®

 system

4. Starting DCC-Operation

Place  the  locomotive  on  the  programming  track 
and read out the locomotive address. The default 
for this address is 03.
Should  the  command  station  display  read  “error” 
please  check  the  wiring  of  the  locomotive  once 
again. Please note the following advice:

Using the Intellibox from Uhlenbrock – possi-
bly also with other digital central units – there 
is the possibility of an error message at the 
beginning of programming, so that any fur-
ther application of the CVs is not possible. 
To solve this problem you have to insert a 
47 ohm resistor at one of the cables of the 
programming track.

If  the  address  is  correct,  you  may  now  test  the 
functionality  (e.g.  direction  of  the  motor  rotation, 
lights etc.) of the locomotive.
After this initial test you may adapt the settings to 
match your own requirements (e.g. address, load 
control etc.).

Notwithstanding  to  the  sketches  of  the 
enclosed manual art.no. 5254 the connector 
for the auxiliary function (“ZF”) is at the place 
shown at the picture on the top.

5. DCC-Programmierung

The operation characteristics of the locomotive can 
be  changed  without  limitation  through  program-
ming of the so called confi guration variables (CVs). 
Follow  the  instructions  of  your  digital  command 
station when programming.
For the programming please note the table of the 
relevant CVs at page 4.

Summary of Contents for 5252

Page 1: ...161 for DCC and SELECTRIX 5252 H0 TT N Z 5252 1 Einleitung 2 2 Merkmale 2 3 Einsatz 2 4 Inbetriebnahme DCC Betrieb 2 5 DCC Programmierung 2 6 Einstellmöglichkeiten DCC 4 1 Introduction 3 2 Properties 3 3 Operation 3 4 Starting DCC Operation 3 5 DCC Programming 3 6 Setting Possibilities DCC 4 ...

Page 2: ...ls die ordnungs gemäße Verdrahtung der Lok Beachten Sie dazu auch den folgenden Hinweis Bei der Intellibox der Fa Uhlenbrock unter Umständen auch bei anderen Digitalzentra len kann bei Programmierungsbeginn eine Fehlermeldung auftreten so dass eine wei tere Eingabe von CV Werten unmöglich ist Abhilfe schafft ein Widerstand von 47 Ohm der in eine der Zuleitungen zum Program miergleis einzufügen ist...

Page 3: ... system 4 Starting DCC Operation Place the locomotive on the programming track and read out the locomotive address The default for this address is 03 Should the command station display read error please check the wiring of the locomotive once again Please note the following advice Using the Intellibox from Uhlenbrock possi bly also with other digital central units there is the possibility of an er...

Page 4: ...CTRIX 1 7 1 7 5 7 Versionsnummer Manufacturer version no 52 8 Herstelleridentnummer Manufacturer ID 109 17 Lange Adresse oberes Byte Extended address upper byte 18 Lange Adresse unteres Byte Extended address lower byte 29 Konfigurationsregister Para metrierung Bit 0 Wert 1 Umschaltung der Fahrtrichtung Bit 1 Wert 2 28 128 Fahrstufen Bit 2 Wert 0 kein Analogbetrieb Wert 4 Analogbetrieb Bit 5 Wert 32...

Reviews: