n
DVGW writing
n
green dot for potable water
n
Position indicator on the actuating lever
2.3.5
Compatible components
The model is equipped with Sanfix-P press connections and compatible
with the Sanfix / Sanfix Fosta system.
2.3.6
Technical data
Observe the following operating conditions for the installation of the
model:
Potable water
Heating
Operating tempera‐
ture [T
max
]
70 °C
80 °C
Operating pressure
[P
max
]
1.0 MPa (10 bar)
1.0 MPa (10 bar)
2.4
Information for use
2.4.1
Corrosion
Overground pipelines and fittings in rooms do not normally require
external corrosion protection.
There are exceptions in the following cases:
n
Contact with aggressive building materials such as nitrite or mate‐
rials containing ammonium
n
Contact with aggressive chemicals
n
in aggressive surroundings
If external corrosion protection is required, observe the pertinent guide‐
„Regulations from section: Corrosion“ on page 7
Easytop fittings made of gunmetal/silicon bronze are suit‐
able for all types of potable water.
The chloride concentration in the medium must not exceed
a maximum value of 250 mg/l.
This chloride is not a disinfectant, but in fact pertains to the
content in sea and table salt (sodium chloride).