3 Handling
3.1
Assembly information
3.1.1
Mounting conditions
The model may only be used for the models mentioned in
2.3.1 „Areas of use“ on page 7.
The power pack should be mounted in an easily accessible place to
allow subsequent access.
Before beginning to tile, a concealed socket should be installed for the
power pack with protective pipe to the cistern (installation set
„Optional accessories“ on page 16).
If necessary, the power pack cable can be extended to a length of
4.75 metres (two extension cables
X1
X2
X3
Fig. 10: Installation position of the power pack
X1 max. 0.75 m
X2 max. 2.75 m with an extension cable (article number 628 505)
X3 max. 4.75 m with two extension cables (article number 628 505)
An extension of the mains supply by more than 5 metres
can lead to a situation in which the power is not sufficient to
actuate the flush.
Protected zone
Installation position of the power pack
Handling
WC flush actuation