background image

for wall-mounted cisterns by various manufacturers

Model

Year built:

8310.76

from  04/2017

en_INT

Filling valve set

Instructions for Use

Summary of Contents for 8310.76

Page 1: ...for wall mounted cisterns by various manufacturers Model Year built 8310 76 from 04 2017 en_INT Filling valve set Instructions for Use...

Page 2: ...Filling valve set 2 from 12...

Page 3: ...otes 4 1 3 About this translated version 5 2 Product information 6 2 1 Area of application 6 2 2 Product description 6 3 Handling 7 3 1 Assembly 7 3 1 1 Mounting the filling valve set 7 3 1 2 Cleaning...

Page 4: ...he installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside...

Page 5: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The rele...

Page 6: ...valve set is intended for filling a flush mounted cistern 2 2 Product description 1 2 3 4 5 6 Fig 1 Filling valve set 1 filling valve 2 union nut 3 nipples 4 Clamp connector 5 cistern fastening 3 pc...

Page 7: ...Place the spacer on Insert the group consisting of union nut and spacer in the filling valve Hand tighten the union nut Push the filling valve with the nipple through the opening of the cis tern and f...

Page 8: ...th the nipple through the opening of the cis tern and fasten it Fasten the nipple from the outside at the cistern Connect the nipple with union nut flexible hose or Cu pipe clamp connector Handling Fi...

Page 9: ...3 1 2 Cleaning replacing the membrane valve Dismantle the filling valve Fold up the catches on the cover Remove the cover upwards Handling Filling valve set 9 from 12...

Page 10: ...holder for the float Slide the holder downwards Use snipe nose pliers to release the fixing rim by rotating through 45 in anti clockwise direction Remove the closing piece Handling Filling valve set...

Page 11: ...not dismantle the membrane valve into its compo nents to avoid damage If necessary clean the membrane valve by holding it under running water Mount the membrane valve checking for correct seating Han...

Page 12: ...the cover Mount the valve in the cistern see Chapter 3 1 1 Mounting the filling valve set on page 7 Check the function 3 2 Disposal Separate the product and packaging materials e g paper metal plastic...