3.2.2
Mounting the drain
Proceed as follows to mount the drain:
Place the double seal onto the drain unit in such a way that the
recess is positioned over the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below.
Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
INFO! The cross-shaped structures of the drain units and the
valve top must be positioned parallel on top of each other to
ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using the
mounting aid.
3.2.3
Connecting overflow and drain
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Handling
Multiplex Trio drain/overflow functional unit
14 from 20