Install the base unit horizontally into the base pipeline.

Observe flow direction!

At maximum, line up to the middle of the drainpipe.

Close emergency shut-off (position 

"

OFF

).

In this way, damage from flooding can be avoided before commis-
sioning.

3.3

Care and maintenance

3.3.1

Maintenance

DIN 1986-3 requires 

"

Maintenance

"

 of the system twice a year to ensure

safe operation.

Requirements:

n

Maintenance must be carried out by a professional.

n

Only use original parts for repairs, maintenance and extensions.

n

Replace defective components, do not repair.

n

When using cameras and cleaning devices (cleaning spiral, high-
pressure cleaner), protect the backflow trap against mechanical
damage.

n

Only begin maintenance work when is certain that there is no back
flow situation and the drainage fittings upstream from the Backflow
trap are not being used.

Clean

Handling

Grundfix backflow trap type 1

11 from  14

Summary of Contents for 4987.2

Page 1: ...for faeces free wastewater pipe Model Year built 4987 2 from 01 1996 en_INT Grundfix backflow trap type 1 Instructions for Use...

Page 2: ...Grundfix backflow trap type 1 2 from 14...

Page 3: ...as of use 6 2 2 2 Place of installation and installation conditions 7 2 2 3 Maintenance 8 2 3 Product description 9 2 3 1 Overview 9 2 3 2 Operating mode 9 2 3 3 Control elements 9 3 Handling 10 3 1 A...

Page 4: ...t extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of n...

Page 5: ...Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant n...

Page 6: ...tion EN 13564 2 2 Intended use 2 2 1 Areas of use The backflow trap is suitable for use in drain pipelines made of HT or sewer pipe DN 100 125 or 150 When using other pipes such as e g clay pipes or...

Page 7: ...2 2 2 Place of installation and installation conditions 1 5 4 2 3 Fig 1 Wrong place of installation of the backflow trap Product information Grundfix backflow trap type 1 7 from 14...

Page 8: ...e that drainage is permanently guaranteed backflow traps may not be employed as the central safeguard for a building with drainage equipment installed above the backflow level 1 in the event of backfl...

Page 9: ...nit 2 3 2 Operating mode In the case of backflow the pipeline will be closed by the shutter valve in the backflow trap In addition the shutter valve can be closed man ually using a manual actuator 2 3...

Page 10: ...5 545 125 260 105 75 405 215 550 160 295 125 95 470 245 640 3 2 Assembly 3 2 1 Mount base unit The installation in the drainage pipeline may only be carried out by con struction or specialised sanitar...

Page 11: ...ensure safe operation Requirements n Maintenance must be carried out by a professional n Only use original parts for repairs maintenance and extensions n Replace defective components do not repair n W...

Page 12: ...Place the emergency lock to ZU OFF position Loosen screws on the lid Carefully remove lid Remove and clean flap Handling Grundfix backflow trap type 1 12 from 14...

Page 13: ...ck seal if necessary replace Clean casing Grease the seal of the partition on the casing side with silicon grease Install flap Position and screw on lid Handling Grundfix backflow trap type 1 13 from...

Page 14: ...actuator check functionality 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements...

Reviews: