66250705-EN - V5.1 - 30/09/20
- 5 -
VRVK/6758 Series “6 wire Bus” Vandal Resistant videokit
VRVK/6758 Series - Installation handbook
General directions for installation
CONNECTION TO MAINS
The system must be installed according to national rules in force, in particular we recommend to:
• Connect the system to the mains through an
all-pole circuit breaker
which shall have contact separation of at least 3mm in each
pole and shall disconnect all poles simultaneously;
• The
all-pole circuit breaker
shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
• Remove the terminal side covers by unscrewing the retaining screws;
• Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
• Switch o
ff
the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams;
• Check the connections and secure the wires into the terminals;
• Replace the terminal covers and
fi
x them using the relevant screws;
• After completing the wiring, double check all connections then restore the mains.
CABLE SIZE
Video connections and Audio connections must be wired in twisted pair: pair the video lines (terminals/signals “V1” and “V2”),
pair the audio lines (terminals /signals “1” and “2”).
IMPORTANT NOTE: SOLID COPPER CABLES MUST BE USED. COPPER COATED STEEL
(
CCS
)
AND COPPER COATED
ALUMINIUM
(
CCA
)
CAN NOT BE USED ON THE SYSTEM.
+V *
–
*
1
V1
V2
2
Power
supply
Videophone
Up to 40mt
2 wires
Ø 1mm
2
20mt max
Outdoor
station
BROWN
ORANGE
BLUE
GREEN
WHITE/BROWN
WHITE/ORANGE
WHITE/BLUE
WHITE/GREEN
Distance Suggested cables type
Up to
40mt
CAT5/CAT6
FTP/UTP/CW1308
AWG24/0.22mm
2
* Double up the two wires to increase
the cross section and reduce the re-
sistance.
1
V1
V2
+V
–
2
1
V1
V2
+V
–
2
1
V1
V2
+V
–
2
Power
supply
Videophone
Up to 50mt
Outdoor
station
Outdoor
station
Outdoor
station
"+V" and "–"
Ø 0.35mm
2
"V1" and "V2"
Ø 0.35mm
2
Twisted pair
"1" and "2"
Ø 0.35mm
2
Twisted pair
20mt max
2 wires
Ø 1mm
2
from 50 to 100mt
"+V" and "–"
Ø 0.75mm
2
"1" and "2"
Ø 0.5mm
2
Twisted pair
"V1" and "V2"
Ø 0.5mm
2
Twisted pair
from 100 to 200mt
"+V" and "–"
Ø 1.5mm
2
"V1" and "V2"
Ø 0.75mm
2
Twisted pair
"1" and "2"
Ø 0.75mm
2
Twisted pair
Distance Suggested cables type
Up to
50mt
4 pair (8 cores) 0.35mm
2
AWG22 - 48
Ω
/Km
From
50 to
100mt
3 pair (6 cores) 0.8mm
2
AWG18 - 19.2
Ω
/Km
From
100 to
200mt
4 pair (8 cores) 0.8mm
2
AWG18 - 19.2
Ω
/Km
Summary of Contents for VRVK-1/6758
Page 24: ...66250705 EN V5 1 30 09 20 24...
Page 25: ...66250705 EN V5 1 30 09 20 25...
Page 28: ...66250705 EN V5 1 30 09 20 28...
Page 29: ...66250705 EN V5 1 30 09 20 29...
Page 30: ...66250705 EN V5 1 30 09 20 30...