background image

66250705-EN - V5.1 - 30/09/20

- 17 -

VRVK/6758 Series “6 wire Bus” Vandal Resistant videokit

VRVK/6758 Series - Installation handbook

Art.

 

6758 

 7" hands free colour display digital videomonitor

27mm

200mm

150mm

Fig. 1  

 

PT2 PT3

PT1

SW1

VR1

6

7

8

1

2

3

5

4

ON

DSW1

DSW2

1

2

ON

V2

V1

2

1

+V

4A 5A 12

M

3A

2A

LD

SB

LB

A

B

C

H

G

F

D

E

Fig. 2  

 

DESCRIPTION

Surface mount hands free videophone incorporating a 7” Hi-Res 

full  colour  active  matrix  LCD  monitor  speci

fi

c  for “6  wire”  vid-

eokit (VK4K, VRVK and VK8K range). It includes 4 buttons: “cam-

era recall” “open door” “service” and “privacy”. 

3 LED’s* indicate the privacy activated , open door and activat-

ed functions.

Programmable  privacy  duration,  meldy  type  and  number  of 

rings. Intercommunicating call and door call.

Adjustments:  call  tone  volume  switch  (3  levels),  picture  hue, 

contrast and brightness.

* The operation of some LED’s and the functions described may require additional cabling

.

LEGEND

A

  Connection terminals

B

  8 Way dip switch bank to set videophone address

C

  2 Way dip switch bank to set video mode

D

  Hue adjustment trimmer

E

  Contrast adjustment trimmer*

F

  Speech volume control

G

  Brightness control

H

  Call tone volume switch

* Not available in some LCD versions.

PUSH BUTTONS

Service push button.

Shorts the 

SB

 terminal to GROUND (open collector 24Vdc 100mA max) while the button remain pressed.

Privacy ON-OFF button.

When the system is in stand-by, the pressing of this button activates (LED switched on) or disables (LED switched o

ff

) the 

“privacy” service. The service is automatically disabled when the programmed privacy time expires. When the service is 

enabled the videophone does not receive calls.

Door-open / intercommunicating call button.

With speech lines open to the entrance panel, press this button to open the door. If the terminal 

LD

 is properly connected 

the relevant LED remains switched ON until the door is closed.

Intercommunication only works when the system is in the stand-by condition.

Switch 4 of the SW1 dip-switch selects the type of intercommunication:

OFF

 Intercommunication between two apartments - press the key button to call the videophone(s) in the other apartment. 

A busy tone will signal that the other videophone is in conversation with the door station and so cannot be called.

ON

  Intercommunication between videophones in the same apartment

- press the key button one, two, three or four times to call videophone with extension address 1, 2, 3 or 4 (Set on dip-switches 

2&3 of SW1).

Any intercommunicating conversation is always interrupted by an external call (i.e. External calls take priority).

Intercommunication push button.

For an intercommunicating call, press as many times as the extension or address value to call (see SW3 Intercommunication 

Settings).

Summary of Contents for VRVK-1/6758

Page 1: ...OKIT VRVK 6758 SERIES 6 Wire bus one way two way vandal resistant videokit Installation handbook We recommend This equipment is installed by a Competent Electrician Security or Communications Engineer...

Page 2: ...bell Push to exit Door monitor Some diagrams show how to connect a 12Vdc electric lock these directions are suitable for all diagrams in this manual Each time a setting is changed on a videophone add...

Page 3: ...1 button speaker unit 1 Art 4852 Flush mounting box 1 Colour videophone Art 6758 1 Power supply Art 850K VRVK 1S 6758 surface mounting 1 Outdoor station composed of 1 Art VR4KCM Camera unit 1 Art VR4...

Page 4: ...ounting box 1 Colour videophone Art 6758 1 Power supply Art 850K VRVKC 1S 6758 surface mounting 1 Outdoor station composed of 1 Art VR4KCM Camera unit 1 Art VR4KAMK 1 1 button speaker unit 1 Art VR490...

Page 5: ...connections then restore the mains CABLE SIZE Video connections and Audio connections must be wired in twisted pair pair the video lines terminals signals V1 and V2 pair the audio lines terminals sig...

Page 6: ...nal During the conversation it is not possible to open the door but the key LED on the door station switches on for the program med time Incorrect position of J2 jumper Electriclockwiresunconnectedori...

Page 7: ...cable or for balanced video twisted pair cable LEGEND A Camera and illumination LED s B Video signal mode jumper C Camera switching on mode jumper D Terminals VIDEO SYSTEM SETUP The video system setup...

Page 8: ...deo signal sync V1 Balanced video signal sync V Coax video signal Ground input SB Heater plus input 12V 20 20Vdc power supply input 12 12Vdc power supply input TECHNICAL SPECIFICATION Working voltage...

Page 9: ...me G Loudspeaker volume H 4 way dip switch I Jumpers L Connection terminals M Button wires AVAILABLE VERSIONS Art VR4KAMK 0 Art VR4KAMK 1 Art VR4KAMK 2 Art VR4KAMK 3 Art VR4KAMK 1NP LEDS Yellow SPEAK...

Page 10: ...te either as dry contact or capacitive discharge mode In dry contact operation mode the relay works in a traditional way a power supply or a power source is needed to operate the lock 12 24Vac dc 2A m...

Page 11: ...lyclosedcontact C Door open relay common contact PTE Active low input to control directly the door open relay SL Active low output to enable the enslavement relay for video signal exchange active with...

Page 12: ...odes one for each relay Each relay can be set to be activated for a specific time 01 to 99 seconds or to work as latch Two active low inputs to command directly the relay 1 and 2 Programming menu guar...

Page 13: ...Mode 2 A or B A B A B or Back light on full brightness all of the time JPL removed in either Mode A B No back light the back light is completely disabled PROGRAMMING MODE 1 DEFAULT MODE JPL A Follow t...

Page 14: ...ong code is entered a continuous melody will sound for 4 or more seconds according to the number of mistakes To switch off any relay while operating type in the relevant code then press the CLEAR butt...

Page 15: ...tion handbook 4000 SeriesSurface and flush mounting door station installation EXAMPLE INSTALLING A FOUR MODULE OUTDOOR STATION H G H Y G C F E D B A C L H L P O N M H M M C Q P C D W N N C H fig 1 fig...

Page 16: ...tested and is working correctly move back the module support frames carefully fix them to the surface box using the screwdriver provided P torx end and the pin machine torx screws Q Fig 11 Note do no...

Page 17: ...nal to GROUND open collector 24Vdc 100mA max while the button remain pressed Privacy ON OFF button When the system is in stand by the pressing of this button activates LED switched on or disables LED...

Page 18: ...lash rapidly release the button to listen LED will flash slowly If the button is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when another...

Page 19: ...SIGNALS V 20Vdc Input Output As input 16 20Vdc 0 5A as output 20Vdc 0 5A max Ground reference for V terminal 1 Speech line output from microphone and data signal Approx 12V in stand by 5V during a con...

Page 20: ...hole F Fig 4 If you use the flush mounting box 503 embed it into the wall vertically at approx 140cm from the finished floor and the base 4 Following Fig 4 make the holes B insert the wall plugs C an...

Page 21: ...eo signal In white plastic ABS box 11x70x30mm surface mount ART 316N As Art 316 but small form factor without terminals to connect plus and minus from videophones is required an external connection of...

Page 22: ...17 27 02 2017 Push to Exit Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema necessario togliere l alimentazione di rete...

Page 23: ...dc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max 4 3 2 1 ON J1 VR4KAMK 2 Art 140 J2 1 2 Local Bell Local Bell Coax NC SL ON Art VR4KCMC N Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto...

Page 24: ...66250705 EN V5 1 30 09 20 24...

Page 25: ...66250705 EN V5 1 30 09 20 25...

Page 26: ...dc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max 4 3 2 1 ON J1 VR4KAMK 2 Art 140 J2 1 2 Local Bell Local Bell Coax NC SL ON Art VR4KCMC N Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto...

Page 27: ...t J1 VR4KAMK 1 Art 140 J2 4 3 2 1 ON Coax Balanced SL ON Art VR4KCM 1 ID1 ID2 Coax NC SL ON Art VR4KCMC N Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 07...

Page 28: ...66250705 EN V5 1 30 09 20 28...

Page 29: ...66250705 EN V5 1 30 09 20 29...

Page 30: ...66250705 EN V5 1 30 09 20 30...

Page 31: ...unicipauxenm lange L utilisateurdoitdoncremettrel quipementenfinde vieauxcentresdecollecteappropri soulerestitueraurevendeurlorsdel achatd unnouveautyped quipement quiva lent danslerapportdeun un Depl...

Page 32: ...Center Twente BCT Grotestraat 64 NL 7622 GM Borne www videxintercom nl info videxintercom nl El producto lleva la marca CE que demuestra su conformidad y puede ser distribuido en todos los estados mi...

Reviews: