66550033-EN - V6.1 - 15/08/20
- 14 -
ESVK/6388 Series “2 wire Bus” videokit
ESVK/6388 Series - Installation handbook
PROGRAMMING TAGS (ONLY ART. 4384X VERSIONS)
MASTER TAG
The external module is supplied with a master tag. The master tag is programmed in-factory, it is white to easily stand out. This tag
enables user tags to be programmed or cleared.
If the master tag is lost, a new one will have to be ordered and a specific procedure performed to program it on the external module.
In this instance, it will be necessary to reprogram all the user tags.
USER TAG
The user tags can be programmed on the external module using the master tag to access programming mode:
1. Place the master tag in front of the tag reader.
↪
The external module emits two high-pitched
“bip”.
BIP BIP
2. Press the call button (the lower call button in the case of a 2-button external module).
↪
The external module emits a low-pitched continuous
“beeping”
sound.
BIIIIIIP
3. Release the call button.
↪
The low-pitched
“beeping”
sound stops.
4. Place the user tag to be programmed in front of the tag reader.
↪
The external module emits a high-pitched
“beeping”
sound, the tag is programmed. If you do
not remove the tag quickly, may be emitted the alert for an already programmed tag.
BIP
5. Repeat the step 4 for each tag to program.
Note:
the external module emits three low-pitched
“beeping”
sounds if an already programmed
tag is placed in front of the tag reader.
BIP BIP BIP
Note:
the external module emits three high-pitched
“beeping”
sounds to indicate that its
memory is full (50 tags maximum). In this instance, it is not possible to program new tags.
BIP BIP BIP
6. To exit programming mode:
» place the master tag in front of the tag reader, or
» wait 10 seconds after the most recent programming operation.
↪
The external module emits two low-pitched
“beeping”
sounds in order to indicate
that it is in operational mode.
BIP BIP
USING TAGS
Place a tag in front of the tag reader:
↪
If the tag is programmed, the external module emits two high-pitched
“beeping”
sounds
and its relay is activated.
BIP BIP
↪
If the tag is not programmed, the external module emits three low-pitched
“beeping”
sounds and its relay is not activated.
BIP BIP BIP
CLEARING USER TAGS
The following procedure will clear the programming on all user tags.
Clearing the user tag programming is carried out on the external module using the master tag to run the procedure:
1. Place the master tag in front of the tag reader.
↪
The external module emits two high-pitched
“bip”.
BIP BIP
2. Press the call button (the lower call button in the case of an external 2-button module) BIP.
↪
The external module emits a low-pitched continuous
“beeping”
sound.
BIIIIIIP
3. Release the call button.
↪
The low-pitched
“beeping”
sound stops.
4. Press and hold down the call button and place the master tag in front of the tag reader.
↪
The external module emitts two low-pitched
“beeping”
sounds, all user tags have been
cleared and the external module exits programming mode.
BIP BIP
Art. 4384
Speaker unit with built-in camera
Art. 4384X
Speaker unit with built-in camera & proximity key reader