8.14 Hardware configuration
8.14.1 Opening the configuration door
Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration window. Open the hatch by undoing
the screws as shown in figure.
Fig.
65
The DIP-switches appear as shown in the figure.
Fig.
66
After installation and wiring, close the
product again.
8.14.2 DIP1 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
Switch 1 is used to update the firmware.
Switches 4, 3 and 2 are used to select the
communication rate of the device.
Fig.
67
DIP1 CONFIGURATION
Description
SW
4
SW
3
SW
2
SW
1
Baud rate
Baud rate
adjustment
OFF OFF OFF –
300 baud
ON
OFF OFF –
600 baud
OFF ON
OFF –
1200 baud
ON
ON
OFF –
2400 baud
OFF OFF ON
–
4800 baud
ON
OFF ON
–
9600 baud
OFF ON
ON
–
19200 baud
ON
ON
ON
–
38400 baud
Firmware update
–
–
–
ON
Set up enabled
–
–
–
OFF Set up disabled
Fig.
68
8.14.3 DIP2 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
The Pan & Tilt can be controlled via various protocols.
Fig.
69
DIP2 CONFIGURATION
Protocol
SW
8
SW
7
SW
6
SW
5
SW
4
SW
3
SW
2
SW
1
PTZ Manager1
OFF OFF OFF OFF OFF OFF OFF OFF
MACRO
(VIDEOTEC)
OFF OFF OFF OFF OFF ON ON ON
PANASONIC
OFF OFF OFF ON OFF ON OFF OFF
PELCO D
OFF OFF OFF OFF ON OFF OFF ON
AMERICAN
DYNAMICS
OFF OFF OFF OFF ON ON ON OFF
VISTA
OFF OFF OFF ON OFF OFF ON ON
Tab.
13
1
Deafult configuration: MACRO (VIDEOTEC), 115200
baud, Address 1. This option does not require the
setting of the DIP-switch (DIP1, DIP3).
Tab.
14